beautypg.com

6 installation, 1 flange caps and gaskets, 2 grounding – Richter BVIP/F Series Ball Valves (ISO/DIN) User Manual

Page 9: 3 direction of flow and installation position, 4 test pressure, Flange caps and gaskets, Grounding, Direction of flow and installation position, Test pressure, 6installation

background image

Series BVI/F, BVIP/F

Page 9

9520-090-en

Revision 10

TM 8361

Edition 10/2011

6

Installation

Examine valve for in-transit damage, damaged ball
valves must not be installed.

Before installation the valve and the connecting
pipe must be carefully cleaned to remove any dirt,
especially hard foreign matter.

During installation, pay attention to the correct
tightening torque, aligned pipes and tension-free
assembly.

Ensure that a remotely actuated actuator
cannot be accidentally switched on.

6.1 Flange caps and gaskets

Leave protective caps on the flanges until just prior
to installation.

Where there is a particularly high risk of damage to
the plastic sealing surfaces, e.g. if the mating flanges
are made of metal or enamel, PTFE-lined gaskets
with a metal inlay should be used. These gaskets are
available as special accessories in the Richter range.

6.2 Grounding

The valve must be grounded. The simplest solution is
to use tooth lock washers which are placed under one
pipe bolt of each flange.

Otherwise grounding must be ensured by different
measures e.g. a cable link.

At the customer's request a setscrew M6 with a hex.
nut and washer will be provided at each flange as an
additional grounding connection.

Ball/stem unit 201 and stem 202 are grounded using a
grounding spring washer 557.

6.3 Direction of flow and

installation position

Installation is independent of the direction of flow.

Any installation position can be chosen.

Otherwise, it is marked by a direction arrow on the ball
valve, in the case of an additional relief bore in the
ball/stem unit or the ceramic ball.

Fig. 1 Ball Al

2

O

3

in closed position

Fig. 2 Ball/stem unit in closed position

6.4 Test pressure

The test pressure PT of an open valve must not
exceed the value of 1.5 x PS(PN) as per the
identification of the valve.

This manual is related to the following products: