beautypg.com

List of contents, Relevant documents, Series ksea/f – Richter KSEA/F Series Safety Valves User Manual

Page 2

background image

Series KSEA/F

Page 2

9530-052-en

Revision 03

TM 7128

Edition 05/2008

List of Contents

List of Contents ........................................ 2

Relevant documents................................. 2

1 Technical data...................................... 3

1.1

Name plate and body identification ............. 3

1.2

Tightening torques....................................... 4

1.3

Pressure/temperature diagram ................... 4

2 Safety.................................................... 5

2.1

Intended use................................................ 5

2.2

For the customer / operator......................... 5

2.3

Improper operation ...................................... 5

3 Safety notes for applications in

potentially explosive areas based on
the Directive 94/9/ EC (Atex 95) .......... 6

3.1

Intended use................................................ 6

4 Safety note for valves, certified to

Clean Air Act (TA Luft) ........................ 7

5 Transport and storage......................... 7

5.1

Transport securing for KSEA/F ................... 7

5.2

Storage ........................................................ 7

5.3

Return consignments .................................. 8

5.4

Disposal....................................................... 8

6 Installation............................................ 8

6.1

Sizing of the inlet line .................................. 8

6.2

Sizing of the outlet line ................................ 8

6.2.1

Admissible back pressure

8

6.2.2

Drainage of condensate

9

6.2.3

Discharge conditions and reaction forces

9

6.3

Valve connecting dimensions...................... 9

6.4

Flange caps and gaskets ............................ 9

6.5

Direction of flow and installation.................. 9

6.6

Grounding.................................................. 10

6.7

Installation ................................................. 10

6.8

Blocking screw (option) ............................. 10

6.9

Signal transmitter (Option) ....................... 10

6.10

Design for highly permeating media (Option)
11

6.11

Shortened or no lifting lever (Option) ........ 11

6.12

Travel stop (Option)................................... 11

7 Operation............................................ 12

7.1

Initial commissioning................................. 12

7.2

Shutdown .................................................. 12

7.3

Recommissioning...................................... 12

7.4

Improper operations and their consequences
............................................................... 12

8 Malfunctions....................................... 13

9 Maintenance ....................................... 13

9.1

Screw connections .................................... 14

9.2

Cleaning .................................................... 14

9.3

Modification of the safety valve................. 14

9.4

Adjustment of the test pressure ................ 14

9.5

Important notes on dismantling / installation
14

9.6

Replacement of components .................... 14

9.6.1

Dismantling of the plug

14

9.6.2

Dismantling of the seat

15

9.6.3

Installation of the seat

15

9.6.4

Installation of the plug

15

9.6.5

Installation of the thrust ring

15

9.7

Dismantling KSEA/F 100/150 ................... 15

9.7.1

Dismantling of the entire upper section /
Removal of the seat and plug

15

9.8

Assembly KSEA/F 100/150....................... 16

9.9

Tests ......................................................... 18

9.9.1

Lift 18

9.9.2

Adjustment of set pressure

18

9.9.3

Pressure setting

18

9.9.4

Set pressure tolerances

18

9.9.5

Seat tightness test

18

9.9.6

Seat tightness test with air

19

9.7.7

Leakage test with air

19

9.9.8

Acceptance criteria (air)

19

9.9.9

Seat tightness test with water

19

9.9.10

Leakage test with water

19

9.9.11

Acceptance criteria (water)

19

9.9.12

Back pressure test

19

10 Drawings............................................. 20

10.1

Legend ...................................................... 20

10.2

Sectional drawing KSEA/F........................ 21

10.3

Views......................................................... 22

10.4

Dimensional drawing................................. 23

Relevant documents

Data/Inspection sheet
Declaration of conformity
Form for Safety Information Concerning the
Contamination QM 0912-16-2001_en

On request :

Pressure spring table
Bellows operating ranges, TIS 0587-02-0006