Ballast Operation

WARNING!

1) ALWAYS TURN OFF THE BALLAST BEFORE connecting

or disconnecting Lamps, Harnesses or Extension Cables.

2) Use only with Sine wave inverters. Do not operate on SCR dimmers.

3) If powering the ballasts through a Dimmer Pack, set the Dimmer

to Non-Dim mode.

The 120VAC Ballast requires 110 to 130 Volts AC 50/60 Hertz on an earth

grounded circuit; the 230VAC Ballast requires 220 to 240 Volts AC on an

earth grounded circuit. The electronic Ballast operates at a high frequency of

25 kHz. It is dead-quiet, instant-on and lightweight.

The Ballast operates remote from the fixture. Connect the Extension cable

to the Ballast and the Lamp Harness. After the lamps are properly installed,

the Ballast can be turned on.

Load Considerations

Kino Flo Mega ballasts are not power factor corrected. They will draw

double the current on the neutral from what is being drawn on the two hot

legs. On large installations it may be necessary to double your neutral run

so as not to exceed your cable capacity.

Cold Temperature Operation

The Mega Ballast series is designed to operate at temperatures from 14F

to 122F (-10C to +50C). In cold temperatures, the Ballast may not strike

the lamp(s) instantly. Switch the Ballast to OFF, wait seven seconds and

try again. If the Ballast does not strike after two or three attempts, turn off

the Ballast, check that the Extension and Harness connections are secure

and re-strike. Once operating for a few minutes, the lamps should re-strike

instantly.