Image 87 dmx control panel – Kino Flo Image 87/47 DMX Series User Manual
Page 9

9
Image 87 DMX Control Panel
A)
Manual Selector Dial: Turns lamps on and off manually without
connecting DMX cable to fixture.
B)
HO/Std Selector Switch: HO setting operates lamps at High Output;
Std setting operates lamps at Standard light output.
Note:
Std is ½ f-stop lower than HO.
C)
Power Switch: Turns fixture on and off. Has built-in indicator light to
detect if AC power is present in power cord. “O” = OFF position.
D)
Fuse: Provides circuit protection. Note: If fuse is “blown” or “open”,
replace with same type of fuse rating as marked.
E)
DMX Address: Sets DMX address of fixture.
F)
DMX OK: Lights if DMX signal is present and conforms to DMX512/1990.
G)
DMX Channels: Sets the Image to control all lamps on one channel or
to control lamps individually. Image 87 uses DMX Channel 1 or
DMX Channel 9 (1-8 = Lamps, 9 =
HO/Std). Image 47 uses
DMX Channel 1 or DMX Channel 5 (1-4 = Lamps, 5 =
HO/Std).
The 9th address (5th address for Image 47) controls the
HO/Std setting.
H)
DMX-In & DMX-Out: DMX-In receives signals from Dimmer Board.
DMX-Out relays DMX signals through other fixtures or instruments.
Note: Each Image 87 & 47 DMX fixture has an “AUTO TERMINATE”
feature. The last fixture that does not have an XLR cable attached to the
DMX “Out” port will automatically terminate.
A
B
C D
F
E
G
H
Power
Provide 120VAC or 230VAC depending on model. Do not dim fixture
through a dimming circuit. If powering the fixtures through a dimming
board, set the dimmer profile to non-dim.