Watts Governor 80 User Manual
Series governor 80-m1, Ball cock and thermal expansion relief valve, Installation instructions
IS-80-M1
Series Governor 80-M1
Ball Cock and Thermal Expansion
Relief Valve
CAUTION:
You are required to thoroughly read all installa-
tion instructions and product safety information
before beginning the installation of this product.
FAILURE TO COMPLY WITH PROPER INSTAL-
LATION AND MAINTENANCE INSTRUCTIONS
COULD RESULT IN PRODUCT FAILURE WHICH
CAN CAUSE PROPERTY DAMAGE, AND/OR
PERSONAL INJURY. Watts is not responsible for
damages resulting from improper installation and/
or maintenance.
Local building or plumbing codes may require
modifications to the information provided. You are
required to consult the local building and plumbing
codes prior to installation. If this information is not
consistent with local building or plumbing codes,
the local codes should be followed.
Need for Periodic Inspection/Maintenance:
This product must be tested periodically in
compliance with local codes, but at least once
per year or more as service conditions warrant.
Corrosive water conditions, and/or unauthorized
adjustments or repair could render the product in-
effective for the service intended. Regular check-
ing and cleaning of the product’s internal com-
ponents helps assure maximum life and proper
product function.
Installation Instructions
The Watts Governor 80-M1 is for both existing
and new installations providing an auxiliary relief
feature, a safe antisiphon vacuum breaker and
truly dependable fill valve assembly.
The non-adjustable thermal expansion relief valve
is set standardly at 80psi (552 kPa), 100psi (6.9
bar), or 125psi (8.6 bar) with a maximum operat-
ing temperature of 110°F (135ºC) to meet existing
codes. The Watts Governor 80 is available in three
standard lengths: 10", 11
1
⁄
2
" or 12
1
⁄
2
".
Be sure
maximum water level mark is even with or
above the top of the overflow tube.
Important: This is a control device that limits
system pressure in the event of thermal expansion.
It does not take the place of any safety relief
devices that are required by code. If the incom-
ing water pressure exceeds 65psi (448 kPa), a
pressure reducing valve must be installed at the
service entrance. If the system already contains a
pressure reducing valve, be sure it is set no higher
than 65psi (448 kPa) under a no-flow condition.
Installation Instructions For The Governor
80-M1.
1. Shut off water supply valve. Drain tank.
2. Unscrew water supply line coupling nut from
ball cock shank beneath tank. (A small amount
of water will drain
out.) Slide cou-
pling nut down
water supply line
to be reused. If
replacement is
necessary, a new
coupling nut is provided. (See reverse side.)
3. Unscrew and remove lock nut from ball cock
shank. Remove old ballcock assembly.
4. Thread float rod into lever on top of the
Governor 80-M1. (If your tank requires a longer
threaded float rod, obtain one or reuse float rod
from old ball cock.) Thread the float onto the
float rod.
5. Insert shank through hole in bottom of tank.
Position ball cock inside tank so rod and float do
not rub against flush valve or back of tank. Hold
ball cock steady inside the tank while threading
Typical Water Closet
C.L. = Critical level established
W.O.L. = Water overflow level
▼
▼
1"
“C.L.”
“Governor 80-M1”
“W.0.L.”
Float Ball
Thermal
Expansion
Relief Valve
Overflow
Tube
10",
11
1
⁄
2
"
or
12
1
⁄
2
"
new lock nut onto shank beneath tank. Turn lock
nut until hand-tight, then snug
1
⁄
4
– turn with pli-
ers.
Do Not Overtighten.
6. Reattach coupling nut washer from the end of
water supply line or install new coupling nut
washer provided. Turn snug
1
⁄
4
– turn with pli-
ers.
Do Not Overtighten.
7. Attach refill tube provided onto connector of ball
cock. Then clip the opposite end of refill tube onto
the overflow tube of flush valve so that the end of
refill tube is pointing into the overflow tube.
8. Your new ball cock is ready to use. Turn on
water. Examine for leaks. With no leaks appar-
ent, flush toilet and check for proper water level
of tank when full.
Sometimes slight adjustments have to be made
to maintain the proper water level in the tank. This
can be done by slightly bending the float rod. Bend
rod upward to allow more water into the tank or
bend downward to reduce water level.
Installation Instructions For Governor 80-
M1 Service Kit.
1. Shut off water supply valve and flush toilet.
2. Unscrew cap ring (counterclockwise). Slide
ring over lever assembly and rest it on float.
Remove top works (cap, lever assembly,
plunger and both diaphragms).
3. Remove and replace relief valve.
Note: Do not use Teflon
®
tape or pipe dope. Do
not overtighten.
4. Insert new diaphragms and reassemble top
works.
Note: Position lever assembly so that notched
parts are aligned,
before attaching cap ring.
5. Turn on water. Examine for leaks and proper
water level.
Repair Kit: RK GOV80-D
Ordering Code: 0721478
Consists of: 1 - Upper diaphragm
1 - Lower diaphragm
1 - Relief valve #32-80
Black Rubber
Gasket
Lock Nut
Water Supply
Coupling Nut
Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and
workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects
within the warranty period, the Company will, at its option, replace or recondition the product without charge.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY
WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE
COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach
of warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including
without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not
work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material,
damage from adverse water conditions, chemical, or any other circumstances over which the Company has no control.
This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or
alteration of the product.
Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion
or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This Limited
Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult
applicable state laws to determine your rights.
SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED
WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL
SHIPMENT.
IS-80-M1 1140
EDP# 1915307
© 2011 Watts
A Watts Water Technologies Company
USA: No. Andover, MA • Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com