beautypg.com

Watts Governor 80 User Manual

Series governor 80-m1, Ball cock and thermal expansion relief valve, Installation instructions

background image

IS-80-M1

Series Governor 80-M1

Ball Cock and Thermal Expansion

Relief Valve

CAUTION:
You are required to thoroughly read all installa-

tion instructions and product safety information

before beginning the installation of this product.

FAILURE TO COMPLY WITH PROPER INSTAL-

LATION AND MAINTENANCE INSTRUCTIONS

COULD RESULT IN PRODUCT FAILURE WHICH

CAN CAUSE PROPERTY DAMAGE, AND/OR

PERSONAL INJURY. Watts is not responsible for

damages resulting from improper installation and/

or maintenance.
Local building or plumbing codes may require

modifications to the information provided. You are

required to consult the local building and plumbing

codes prior to installation. If this information is not

consistent with local building or plumbing codes,

the local codes should be followed.
Need for Periodic Inspection/Maintenance:

This product must be tested periodically in

compliance with local codes, but at least once

per year or more as service conditions warrant.

Corrosive water conditions, and/or unauthorized

adjustments or repair could render the product in-

effective for the service intended. Regular check-

ing and cleaning of the product’s internal com-

ponents helps assure maximum life and proper

product function.

Installation Instructions

The Watts Governor 80-M1 is for both existing

and new installations providing an auxiliary relief

feature, a safe antisiphon vacuum breaker and

truly dependable fill valve assembly.
The non-adjustable thermal expansion relief valve

is set standardly at 80psi (552 kPa), 100psi (6.9

bar), or 125psi (8.6 bar) with a maximum operat-

ing temperature of 110°F (135ºC) to meet existing

codes. The Watts Governor 80 is available in three

standard lengths: 10", 11

1

2

" or 12

1

2

".

Be sure

maximum water level mark is even with or

above the top of the overflow tube.
Important:
This is a control device that limits

system pressure in the event of thermal expansion.

It does not take the place of any safety relief

devices that are required by code. If the incom-

ing water pressure exceeds 65psi (448 kPa), a

pressure reducing valve must be installed at the

service entrance. If the system already contains a

pressure reducing valve, be sure it is set no higher

than 65psi (448 kPa) under a no-flow condition.
Installation Instructions For The Governor

80-M1.
1.
Shut off water supply valve. Drain tank.
2. Unscrew water supply line coupling nut from

ball cock shank beneath tank. (A small amount

of water will drain

out.) Slide cou-

pling nut down

water supply line

to be reused. If

replacement is

necessary, a new

coupling nut is provided. (See reverse side.)

3. Unscrew and remove lock nut from ball cock

shank. Remove old ballcock assembly.

4. Thread float rod into lever on top of the

Governor 80-M1. (If your tank requires a longer

threaded float rod, obtain one or reuse float rod

from old ball cock.) Thread the float onto the

float rod.

5. Insert shank through hole in bottom of tank.

Position ball cock inside tank so rod and float do

not rub against flush valve or back of tank. Hold

ball cock steady inside the tank while threading

Typical Water Closet

C.L. = Critical level established

W.O.L. = Water overflow level

1"

“C.L.”

“Governor 80-M1”

“W.0.L.”

Float Ball

Thermal

Expansion

Relief Valve

Overflow

Tube

10",

11

1

2

"

or

12

1

2

"

new lock nut onto shank beneath tank. Turn lock

nut until hand-tight, then snug

1

4

– turn with pli-

ers.

Do Not Overtighten.

6. Reattach coupling nut washer from the end of

water supply line or install new coupling nut

washer provided. Turn snug

1

4

– turn with pli-

ers.

Do Not Overtighten.

7. Attach refill tube provided onto connector of ball

cock. Then clip the opposite end of refill tube onto

the overflow tube of flush valve so that the end of

refill tube is pointing into the overflow tube.

8. Your new ball cock is ready to use. Turn on

water. Examine for leaks. With no leaks appar-

ent, flush toilet and check for proper water level

of tank when full.

Sometimes slight adjustments have to be made

to maintain the proper water level in the tank. This

can be done by slightly bending the float rod. Bend

rod upward to allow more water into the tank or

bend downward to reduce water level.
Installation Instructions For Governor 80-

M1 Service Kit.
1.
Shut off water supply valve and flush toilet.
2. Unscrew cap ring (counterclockwise). Slide

ring over lever assembly and rest it on float.

Remove top works (cap, lever assembly,

plunger and both diaphragms).

3. Remove and replace relief valve.
Note: Do not use Teflon

®

tape or pipe dope. Do

not overtighten.
4. Insert new diaphragms and reassemble top

works.

Note: Position lever assembly so that notched

parts are aligned,

before attaching cap ring.

5. Turn on water. Examine for leaks and proper

water level.

Repair Kit: RK GOV80-D

Ordering Code: 0721478
Consists of: 1 - Upper diaphragm

1 - Lower diaphragm

1 - Relief valve #32-80

Black Rubber

Gasket

Lock Nut

Water Supply

Coupling Nut

Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and

workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects

within the warranty period, the Company will, at its option, replace or recondition the product without charge.

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY

WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE

COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT

LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach

of warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including

without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not

work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material,

damage from adverse water conditions, chemical, or any other circumstances over which the Company has no control.

This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or

alteration of the product.

Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion

or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This Limited

Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult

applicable state laws to determine your rights.

SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED

WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND

FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL

SHIPMENT.

IS-80-M1 1140

EDP# 1915307

© 2011 Watts

A Watts Water Technologies Company

USA: No. Andover, MA • Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com

Canada: Burlington, ON • Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca