beautypg.com

Watts LF008PCQT User Manual

Series lf008pcqt, Lead free, Sizes

background image

Series LF008PCQT

Health Hazard, Anti-Siphon,

Spill-Resistant Backflow Preventer

Sizes:

3

8

",

1

2

",

3

4

" and 1" (10, 15, 20, 25mm)

Series LF008PCQT is designed for indoor point-of-use applica-

tions to prevent backsiphonage of contaminated water back

into the potable water supply. Separation of the water supply

from the air inlet is accomplished by means of a diaphragm

seal. This feature protects against any spillage during start-up

or operation. The LF008PCQT features Lead Free* construc-

tion to comply with Lead Free* installation requirements.

Features

•  Standardly supplied with internal polymer coating

•  Standardly supplied with Tee handles

•   Available less Tee handle with stem wrench flats. For use 

where space is limited

•  Available in left-handed or right-handed outlet

•  Spill-resistant design for indoor use

•  Affordable design

•  Modular cartridge for ease of service

•  Vent uses an O-ring for reliable operation

•  Lead Free* cast copper silicon alloy body for durability

•  Compact space saving design

•  Satin chrome finish available

Installation

The LF008PCQT is designed to be installed at the point-

of-use. When factory installed deck/machine mounted on

machines or equipment, the critical level of the LF008PCQT

shall be not less than 1" (25mm) above the flood rim. If field

applied for general plumbing applications, the critical level of

the LF008PCQT shall be a minimum of 6" (150mm) above the

flood rim.

Specifications

A spill-resistant vacuum breaker (SVB) shall be installed, in

accordance with the manufacturer’s instructions, as noted

on the plans. The valve shall consist of a one-piece modu-

lar check and float assembly made of engineered thermo-

plastic and housed in a Lead Free* cast copper silicon alloy

body. Springs shall be stainless steel. The Health Hazard,

Anti-Siphon, Spill Resistant Backflow Preventer shall be con-

structed using Lead Free* materials. Lead Free* Health Hazard,

Anti-Siphon, Spill Resistant Backflow Preventer shall comply

with state codes and standards, where applicable, requiring

reduced lead content. The valve shall be constructed with a

molded diaphragm separating the air inlet from the potable

water supply to prevent spillage. The valve shall be a Watts

Series LF008PCQT.

For Health Hazard and Continuous Pressure Applications

ES-LF008PCQT

LF008PCQT

LF008PCQT-L (Left Handed)

LF008PCQT (Right Handed)

FOR INDOOR USE!

Hood Screws

(2 Required)
Vent

Spring

Air Bleed Screw

Bleed O-ring

(not shown)

Test Cock

Shutoff

Valve Assembly

(2 Required)

Hood
Bonnet
O-ring
Vent

O-ring
Body
Retainer
Check

Assembly

Size:

3

8

",

1

2

" (10, 15mm)

Hood
Bonnet
O-ring
Vent

O-ring
Body
Retainer
Check

Assembly

Hood Screw

Vent

Spring

Air Bleed Screw

Bleed O-ring

(not shown)

Test Cock

Shutoff

Valve Assembly

(2 Required)

Size:

3

4

", 1" (20, 25mm)

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

LEAD FREE

*

* The wetted surface of this product contacted by consumable

water contains less than 0.25% of lead by weight.

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––