Specifications, Feed water parameters, Drain flow rates – Watts PWBWMZ 3 Cu. Ft. User Manual
Page 4
4
Specifications
Feed Water Parameters
Do not use this system on water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system !
Minimum inlet pressure: 30 psig
Maximum operating pressure: 125 psig
Minimum water temperature: 34°F (1°C)
Maximum water temperature: 110°F (43°C)
Power
Voltage: 120VAC
Frequency: 60Hz
Power consumption: 7 Watts Maximum
Installation
Location: Indoors (Protect from direct sunlight)
Minimum ambient temperature: 34°F (1°C)
Maximum ambient temperature: 122°F (50°C)
!
moDeL no.
VaLVe
mIneraL tank
sIze
meDIa cubIc
Foot
GraVeL
(Lbs)
peak serVIce
FLow (Gpm)*
pressure Drop
back wash
(Gpm)
FLoor space
L X w X h
PWBWCAL1
Time Clock
9" X 48"
1
10
5
<15
7
16" X 10" X 55"
PWBWCAL15
Time Clock
10" X 54"
1.5
10
7
<15
7
16" X 11" X 62"
PWBWCAL2
Time Clock
12" X 52"
2
30
10
<15
10
17" X 13" X 60"
PWBWCAL3
Time Clock
13" X 65"
3
40
15
<15
15
18" X 14" X 74"
*note: Peak service flow rate is for intermittent use only and is not to be interpreted as continuous service flow rate capability. These systems are designed to treat the domestic water used in a
single family dwelling. For irrigation water treatment or higher volume applications please contact your Watts representative.
moDeL no.
VaLVe
mIneraL tank
sIze
meDIa cubIc
Foot
GraVeL
(Lbs)
serVIce FLow*
(Gpm)
pressure Drop
(psI)
back wash
(Gpm)
FLoor space
LXwXh
PWBWMZ1
Time Clock
9" X 48"
1
10
9
15
7
16" X 10" X 55"
PWBWMZ15
Time Clock
10" X 54"
1.5
10
10
15
7
16" X 11" X 62"
PWBWMZ2
Time Clock
12" X 52"
2
30
10
15
10
17" X 13" X 60"
PWBWMZ3
Time Clock
13" X 65"
3
40
15
15
15
18" X 14" X 74"
moDeL no.
VaLVe
mIneraL tank
sIze
meDIa cubIc
Foot
GraVeL (Lbs)
serVIce FLow*
(Gpm)
pressure Drop
(psI)
back wash
(Gpm)
FLoor space
LXwXh
PWBWGAC1
Time Clock
9" X 48"
1
10
3.7
<15
4
16" X 10" X 55"
PWBWGAC15
Time Clock
10" X 54"
1.5
10
5.5
<15
5
16" X 11" X 62"
PWBWGAC2
Time Clock
12" X 52"
2
30
7.4
<15
7
17" X 13" X 60"
PWBWGAC3
Time Clock
13" X 65"
3
40
11.1
<15
9
18" X 14" X 74"
PWBWGAC4
Time Clock
16" X 65"
4
60
14.8
<15
15
20" X 17" X 74"
Drain Flow Rates -
The drain system these filters
are plumbed to must be able to accept the listed drain
volumes for a period of 27 minutes.
Micro Z™ Filters
9" X 48", 1 cubic ft.
7 gpm
10" X 54", 1.5 cubic ft.
7 gpm
12" X 52", 2 cubic ft.
10 gpm
13" X 65", 3 cubic ft.
15 gpm
Carbon Filters:
9" X 48", 1 cubic ft.
4 gpm
10" X 54", 1.5 cubic ft.
5 gpm
12" X 52", 2 cubic ft.
7 gpm
13" X 65", 3 cubic ft.
9 gpm
16" X 65", 4 cubic ft.
15 gpm
Calcite Filters:
9" X 48", 1 cubic ft.
7 gpm
10" X 54", 1.5 cubic ft.
7 gpm
12" X 52", 2 cubic ft.
10 gpm
13" X 65", 3 cubic ft.