Operation

With sufficient pressure, operation of this system is completely auto-

matic . Dependable operation involves only monitoring system pres-

sure differential, periodic filter changes, and service documentation .

Installation

* Please note: All cartridge filters are preinstalled in the

housings at the factory.

1 . Turn off all equipment to be fed by the system, locate the water

supply shutoff valve to your home or RV and turn it off .

2 . Thread the inlet and outlet fittings into the inlet and outlet of the

system . NOTE: DO NOT OVER TIGHTEN THESE FITTINGS

INTO THE FILTER HEADS.

3. Anchor the system on a wall stud or suitable mounting material

spanning wall studs . System must be vertical, upright and level .

4 . Run a suitable line of at least

1

2

" in diameter from the tap water

source to the inlet on the left side of the system . NOTE: DO

NOT OVERTIGHTEN CONNECTION FITTING INTO SYSTEM.

6. Select the appropriate size tubing for the equipment being fed

and connect it to the outlet fitting of the system . NOTE: DO

NOT OVERTIGHTEN CONNECTION FITTING INTO SYSTEM.

7. Once all inlet and outlet piping has been completed check and

make sure all filter housings are tight . Slowly open the inlet valve

to house or RV and allow the system to reach operating pres-

sure, and check for leaks .

8 . Record the start up date for future filter replacements .
Note: Overtightening components can damage the system

causing water damage and/or system failure.

Maintenance

Routine maintenance of this system involves periodic filter changes .

Cartridges should be changed at least every 6 months or sooner

depending on incoming water quality .

Filter Cartridge Replacement Procedure

IMPORTANT: Determine whether all equipment connected to

the system must be turned off prior to shutting off water supply

from filters.
1 . If required, turn off downstream equipment .
2 . Turn OFF water supply to the system and open faucet to relieve

pressure .

3 . Starting with the housing on the left, unscrew housing by turning

counterclockwise . Remove and discard spent filter and drain

water that remains in the bowl . The sediment filter has a cloth

like appearance . It must be in the 1st housing on the left where

water inlet connects . Continue on to the 2nd housing, the Car-

bon Block filter has a mesh covering and a white rubber gasket

on each end .

4 . Clean inside of housing sump with warm water . If desired, disin-

fect housing using a teaspoon of household bleach. Add to filter

bowl and fill with water . Let stand 5 minutes and then discard

and rinse .

5 . Insert new cartridges into filter housings, making sure filters are

installed from left to right, sediment filter then carbon block filter .

Do not overtighten filter housing, overtightening may damage

O-ring(s), cause water leaks, or affect system performance.
6 . Lubricate O-ring using only a water based lube such as K-Y or

vegetable/Olive oil . Make certain the O-ring is properly posi-

tioned and reinstall filter housings . Tighten housings hand tight .

Check O-ring for damage and replace if damaged or distorted .

7. Slowly turn on water supply to restore water flow to water sys-

tem and check for any leaks .

8 . Record filter change date in this manual .

Winter Shut-Down Procedures

The following procedure is recommended if you are winterizing

your RV or will not be using your RV for an extended period of time

(longer then a month) .
Important: Filter housings will break if water is left in them in

freezing weather conditions
1 . Shut off the water supply to the filter system . If you are draining

your fresh water holding tank, this will stop the water supply into

the filter system .

2 . Drain the water from the system .
3 . Remove both filter housings by rotating counterclockwise .
4 . Slide out old filters and discard . “O-rings” should be saved for

future use .

5 . Filter housing should be left unscrewed from the lids to insure no

cracking due to freezing weather conditions.

6 . Follow Filter Cartridge Replacement Procedure when you are

ready to use system again .