Notice to Installer

• Do not discard this manual after installation. This manual

contains important operation, maintenance and precaution-

ary information. Please present this manual to user/operator/

owner after installation.

• It is strongly encouraged that you read this manual before

installing the system to ensure the best possible installation.

• Installation must conform to all local and state plumbing codes

and regulations.

• Connect system to cold water supply only. Water temperature

cannot exceed 100°F/28°C.

• System

must be installed in a vertical, upright and level

position.

• OneFlow

®

systems

must not be used in conjunction with

polyphosphate or any other scale inhibitor.

• Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or after

the system.

• Notice to user/operator/owner: Please retain this manual for

future reference for parts, maintenance or troubleshooting.

• It is recommended that all personnel responsible for operation

and maintenance of this product read the precautions, operation

and maintenance sections of this manual.

Installation Precautions!

• Do

NOT install system on line pressure above 125psi.

• Do

NOT install system on HOT water line. Failure to limit line

temperature to 100°F may result in housing failure and damage.

• Do

NOT install the system backwards with the feed water line

connected to the outlet.

• Do

NOT use liquid pipe compounds for fitting connections.

USE two to three wraps of Teflon

®

tape.

• Do

NOT solder plumbing connections attached to filter housing

or inlet valve. Inlet valve and filter housing will be damaged by

high temperature.

• Do

NOT allow system to freeze. Turn off water supply to housing

and drain housing if temperature falls below 32°F.

• Do

NOT install system in direct sunlight or where system is

exposed to harsh chemicals or may be subjected to being

struck by moving equipment, carts, mops or any other item

that may cause damage.

ALLOW a minimum of 3” under the housing to allow for filter

replacement.

IF water hammer is evident, install water hammer arrestors

before the OneFlow

®

unit.

• Do

NOT overtighten fitting connections into inlet valve or

housing outlet.

• Always back-up valves and fittings with a wrench when

installing a fitting to avoid turning the valve.

• Do

NOT install the unit behind equipment where it may be

difficult to access the system for filter replacement.

Position the OneFlow

®

unit in a suitable location. The direction of flow

through the OneFlow

®

unit is always left to right; keep this in mind

when determining installation location. Do NOT mount the OneFlow

®

system near any source of heat. Also, do not mount the system above

any device or area that would be adversely effected by water.

Installation

1. Turn off all equipment to be fed by the OneFlow

®

System,

locate water supply shutoff valve and turn OFF

2. Determine if the water line has an existing water treatment

system. If so, examine system for use of polyphosphate or

other scale inhibitors. OneFlow

®

will not be effective if used

in conjunction with other scale inhibitors. Remove the scale

inhibitors from the water line or discontinue installation.

3. Install a

1

/

2

” full-flow ball valve on the water supply side that

will feed the water system.

4. Anchor the OneFlow

®

system on a wall stud or suitable

mounting material spanning wall studs. System must be verti-

cal and upright.

5. Run a suitable line from the

1

/

2

” full-flow ball valve at the tap

water source to the inlet ball valve on the left side of the

OneFlow

®

system. Use 2-3 wraps of Teflon

®

tape and brace

the inlet ball valve on the system with a wrench when con-

necting the feed water line.

NOTE: DO NOT OVERTIGHTEN

CONNECTION FITTING INTO BALL VALVE.

6. Select the appropriate size tubing for the equipment being fed

and connect it to the outlet of the OneFlow

®

System.

NOTE:

DO NOT connect the tubing to the equipment at this time. Prior

to making connection to the equipment, this line will be used to

facilitate flushing the system. As an option, a drain valve in a tee

on the outlet side of the OneFlow

®

system could be provided in

the line to facilitate flushing when changing filters.

7. With OneFlow

®

inlet valve closed, slowly open the

1

/

2

” full-

flow ball valve at the tap water source. Check for leaks.

8. If a drain valve was not installed on the outlet side of the system,

hold the tubing that will connect to equipment in a clean bucket

or over sink or drain. Open the system inlet feed valve and allow

water to flush through system for 2 minutes at the specified

system flow rate to allow air bubbles to escape.

NOTE: NO

ACTIVATION IS REQUIRED FOR THE OneFlow

®

SYSTEM TO

PERFORM PROPERLY. FLUSHING IS RECOMMENDED TO

ALLOW AIR TO ESCAPE THE SYSTEM.

9. Make certain that the end of the tubing to be connected to

the equipment is clean and sanitary.

10. Connect tubing to equipment. Open all water supply valves

and check for leaks.

11. If no leaks, turn on equipment and check for normal operation.
12. Attach the Service Log to the installed OneFlow

®

System and

fill in install date.

i

!

2

Teflon

®