Application Bulletin 355

Installation Instructions for TitrIC pro III

Page 4 of 14

1

6.1432.210

Sample beaker 75 mL made of glass
(for 6.2041.800)

1

6.1432.320

Sample beaker 250 mL made of
glass (for 6.2041.820)

1

6.1453.250

Sample beaker 250 mL made of
polypropylene (for 6.2041.820)

1

6.1459.300

Sample beaker 120 mL made of
polypropylene (250 pieces) (for
6.2041.840)

1

6.1006.510

Metrosep A Supp 5 - 100/4.0

1

6.1006.520

Metrosep A Supp 5 - 150/4.0

1

6.1006.500

Metrosep A Supp 4/5 Guard/4.0

1

6.1030.410

Metrosep A Supp 15 – 100/4.0

6.1030.420

Metrosep A Supp 15 – 150/4.0

1

6.1030.500

Metrosep A Supp 15 Guard/4.0

1

6.1050.410

Metrosep C 4 – 100/4.0

1

6.1050.420

Metrosep C 4 – 150/4.0

1

6.1050.500

Metrosep C 4 Guard/4.0

1

2.849.1030

849 Level Control for Inline Eluent
Preparation

2. Installation

The following is a detailed description of the TitrIC pro III
installation.

We strongly recommend that the individual steps are carried
out in the order given below!

2.1. 815 Robotic USB Sample Processor XL (2T/2P)

The sample processor is placed at the side at which it is
most easily accessible. Please note that the following
procedure refers exclusively to the version in which the
sample processor is located at the left-hand side of the IC
system.

On the left-hand side of the 815 Robotic USB Sample
Processor XL, attach the stand support (6.2001.070)
for the external titration vessel.

Mount both Swing Heads (2.786.0040) onto the 815
(see installation instructions).

Do not screw the robotic arm (6.1462.040) nor the
robotic arm DIS-COVER (6.1462.080) onto the Swing
Head!

 The

Sample Rack supplied is screwed onto the 815.

In the vicinity of the 815 the two canisters (standard
equipment of 815) are placed on the floor: One 10 L
canister is used as a waste container, the second one
as a reservoir for deionized (DI) water used for rinsing
the external cell.

From the smaller opening of the canisters containing DI
water, an M8 PTFE tubing connection of suitable length
is led to the connection box made of white plastic of
membrane pump 1 / tower 1 and connected.

From the front opening of the waste canister an M8
PTFE tubing connection of suitable length is led directly
to membrane pump 1 / tower 2 (black plastic) and
connected.

A more detailed description is given in the instructions for
use of the 815 Robotic USB Sample Processor XL.

2.2. Titrando (2.905.0010)

Directly to the right of the 815 Robotic USB Sample
Processor, place the Titrando with a bottle of titration
solution (0.1 mol/L HCl will be connected to the 20 mL
Dosing Unit and 800 Dosino).

2.3. Conductometer (2.856.0010)

The 856 Conductometer is placed directly at the left of the
Titrando. For detailed information about the usage check the
Instructions of Use of the 856.

Before measurement it is recommended to carry out the
calibration of the cell constant in the flow-through cell of this