Self-Diagnostic Function
AirStation will perform self-diagnosis when the power supply is turned ON, or when the
AirStation is restarted.
If an error occurs, you can identify the error by the DIAG lamp flash number. The DIAG lamp keeps flash-
ing until the power is turned OFF or the AirStation is restarted.
If the front panel DIAG lamp and the side panel DIAG lamp are flashing alternately, the
data is being written. Do not turn OFF the power supply to the AirStation while this is happening.
* The data is written when the firmware is replaced.
Error Details when DIAG Lamp Flashes
If one of the above errors is displayed, try removing the AC adapter from the socket to restart.
If the error is still displayed, send the AirStation directly to TECHWORKS INC./Buffallo Technology repair
center. Please call to TECHWORKS INC./Buffalo Technology obtain RMF#.
No. of
flashes
Status
Explanation
1
RAM check error
Cannot read or write to the internal memory.
2
ROM check error
Cannot read or write to the flash ROM
3
Ethernet LAN error
The Ethernet LAN controller is broken.
4
Wireless LAN error
The Wireless LAN controller is broken.
5
Clock error
The Clock is not set correctly, or the clock battery may
be depleted.
9
Error other than the above