Pressure Loss
If you know Flow/Velocity, Pipe Size and
Length, you can calculate Pressure Loss. If
no Run (Length) is entered, Pressure Loss
per foot is calculated. For this example we will
use the default Material, Steel. Calculate for 2”
Pipe with a Flow Rate of 4 gallons per minute
and then convert to different dimensional units.
KEYSTROKES
DISPLAY
ALL CLEARED
STD SIZE 2
INCH
(Area)
AREA 3.355605
SQ INCH
Enter Flow Rate
GPM 4.
Calculate Pressure Loss
PSI
PER FEET
0.000205
REY 6120.09
PSF
PER FEET
0.029469
inHG
PER FEET
0.000417
HEAD
PER FEET
0.000472
BAR
PER FEET
0.000014
KPA
PER FEET
0.001411
PSI
PER FEET
0.000205
Using values above, add the Run (Length) to calcu-
late the Pressure Loss over the length of the pipe.
KEYSTROKES
DISPLAY
RUN 50
FEET
0
INCH
Calculate Pressure Loss
- 4215 (64 pages)
- 4225-B (52 pages)
- 4225-C (52 pages)
- 44060 (134 pages)
- 4050 Metric Edition (44 pages)
- 4050 (52 pages)
- 4050 v3.1 (52 pages)
- 4050-F (52 pages)
- 4054 (52 pages)
- 4045-B (54 pages)
- 4045 (26 pages)
- 4067 Pocket Reference Guide (52 pages)
- 4067 User Guide (23 pages)
- 4065 v3.0 (108 pages)
- 4065 v3.1 Pocket Reference Guide Construction Master Pro (39 pages)
- 4065 v3.1 Pocket Reference Guide Advanced Consnruction-Math (40 pages)
- 4065 v3.1 User Guide (110 pages)
- 8030 (44 pages)
- 5025 (48 pages)
- 5065 (71 pages)
- 5070-A Pocket Reference Guide (45 pages)
- 5070-B Pocket Reference Guide (46 pages)
- 5070-A User Guide (66 pages)
- 5070-B User Guide (66 pages)
- 4315 (56 pages)
- 4320 (51 pages)
- 4325 (53 pages)
- 4090 (123 pages)
- 4019 (40 pages)
- 4018 (38 pages)
- 4015 (84 pages)
- 4020 (39 pages)
- 4095-A Pocket Reference Guide (36 pages)
- 4095-C Pocket Reference Guide (23 pages)
- 4095-A User Guide (50 pages)
- 4095-B User Guide (68 pages)
- 4095-C User Guide (65 pages)
- 4094 Pocket Reference Guide (38 pages)
- 4094 User Guide (44 pages)
- 8545 (48 pages)
- 4400 (50 pages)
- 8015 (64 pages)
- 8020 (52 pages)
- 8025 (47 pages)