11
Chapter 4
Specifications
5011 Specifications
Power Measurement Characteristics
General
Terminated average power
Frequency Range
40 MHz to 4 GHz
Power Measurement
Range
–20.0 to +10.0 dBm (10 µW to 10
mW)
Maximum Power
2 W avg., 125 W peak for 5 µs
Peak/Average Ratio
12 dB maximum
Accuracy
± (5% of reading
a
+ 1.0 µW)
(excluding mismatch uncertainty)
No correction factors necessary
a. Above 40 °C, when measuring frequencies between 40
and 100 MHz, add 1%.
Input Impedance
50 Ohms (nominal)
Input VSWR:
Typical
Maximum
1.03 (36.6 dB return loss)
1.20 (20.8 dB return loss)
Input Connector
Precision N Male
Output Connector
Male DB-9 to host instrument
Power Supply
From host instrument via cable
connection