Rescueline signal booster, 800 mhz series, Specifications – Bird Technologies 61-89A Series User Manual
Page 2

SPECIFICATIONS
Frequency Range 806-869 MHz
Nominal Gain (dB) +80 dB
Gain Adjustment Programmable attenuation,
0-30 dB, 0.5 dB steps
Output Level Control
Dynamic Range
+55 dBm minimum, with no
attenuation
Maximum Input Level 0 dBm
Maximum Output Power +30 dBm (single carrier)
RF Sampler PA Output sampler
Noise Figure (without attenuation) 3.5 dB maximum
Propagation Delay <1 μs
Operating Temperature Range -30°C to +50° C
Nominal impedance 50 ohms, <1.5:1 VSWR
Input/Output connectors N female
RF Sampler Connectors BNC female
AC Power Input 100-240 VAC; 50-60 Hz
DC Input Voltage +24 to +27 VDC
-48 VDC optional
Unit Power Consumption (AC/DC) <100 VA
Nominal Size 24” x 24” x 8”
Net Weight <80 lbs.
FCC Certification** EZZ5PI031202
Industry Canada Certification** 1940A-PI031202
RescueLine Signal Booster
800 MHz Series
Output Level Control (OLC) Circuit Monitors and Controls RF
Output Power
Maintains maximum required output power while preventing
damage and excessive emissions per FCC requirements
Easy-to-read LED bar graph
Unique OLC DataLog feature facilitates system maintenance and
optimization
Decoupled RF Test Points For Simplified Service
Allow fast system measurements in both uplink and downlink directions
Monitor signals for performance optimization
Integrated design facilitates non-intrusive measurements
Secure, Non-Vented NEMA Enclosure Suitable for Extreme
Indoor and Outdoor Environments
Setup is Performed Through a User Friendly Interface
No Tools Required
Optional Features Available
Comm Card II for remote communications and control
Fiber optic link interface*
Redundant PA configuration*
-48 VDC input*
DC Backup Interface Accepts +24 to +27 VDC and optional
-48 VDC
Microprocessor Controlled Fault Monitoring and Alarming
Ensures Reliable Operation and Flexible Configuration
Control system continuously monitors parameters including voltage,
current, temperature and OLC activity
LEDs on each module quickly annunciate source of fault
Simple, back-lit liquid crystal display (LCD) and switch control
Fault triggers annunciation on panel, alarm contact closure and
internal recording of failed subsystem
Card Cage Modularity
Easy “slide-in” replacement process
Facilitates ease of service and system configuration
SignalBooster_RescueLine-09092013
30303 Aurora Rd.
Solon, OH 44139
866.695.4569
www.bird-technologies.com
*Contact Factory for these models
High Performance Bandpass Filters
Configured to customer requirements and addresses many specifications
requiring custom passbands
Models available with passbands that range from 3 MHz (NPSPAC with excellent
out-of-band rejection) to 18 MHz for full band coverage
Programmable Gain Setting
Ease of initial configuration via front panel
When used in conjunction with OLC DataLog, simplifies post installation adjustments