beautypg.com

Rescueline signal booster, 800 mhz series, Specifications – Bird Technologies 61-89A Series User Manual

Page 2

background image

SPECIFICATIONS

Frequency Range 806-869 MHz

Nominal Gain (dB) +80 dB

Gain Adjustment Programmable attenuation,

0-30 dB, 0.5 dB steps

Output Level Control

Dynamic Range

+55 dBm minimum, with no
attenuation

Maximum Input Level 0 dBm

Maximum Output Power +30 dBm (single carrier)

RF Sampler PA Output sampler

Noise Figure (without attenuation) 3.5 dB maximum

Propagation Delay <1 μs

Operating Temperature Range -30°C to +50° C

Nominal impedance 50 ohms, <1.5:1 VSWR

Input/Output connectors N female

RF Sampler Connectors BNC female

AC Power Input 100-240 VAC; 50-60 Hz

DC Input Voltage +24 to +27 VDC

-48 VDC optional

Unit Power Consumption (AC/DC) <100 VA

Nominal Size 24” x 24” x 8”

Net Weight <80 lbs.

FCC Certification** EZZ5PI031202

Industry Canada Certification** 1940A-PI031202

RescueLine Signal Booster

800 MHz Series

Output Level Control (OLC) Circuit Monitors and Controls RF
Output Power

Maintains maximum required output power while preventing
damage and excessive emissions per FCC requirements

Easy-to-read LED bar graph

Unique OLC DataLog feature facilitates system maintenance and
optimization

Decoupled RF Test Points For Simplified Service

Allow fast system measurements in both uplink and downlink directions

Monitor signals for performance optimization

Integrated design facilitates non-intrusive measurements

Secure, Non-Vented NEMA Enclosure Suitable for Extreme
Indoor and Outdoor Environments

Setup is Performed Through a User Friendly Interface

No Tools Required

Optional Features Available

Comm Card II for remote communications and control

Fiber optic link interface*

Redundant PA configuration*

-48 VDC input*

DC Backup Interface Accepts +24 to +27 VDC and optional
-48 VDC

Microprocessor Controlled Fault Monitoring and Alarming
Ensures Reliable Operation and Flexible Configuration

Control system continuously monitors parameters including voltage,
current, temperature and OLC activity

LEDs on each module quickly annunciate source of fault

Simple, back-lit liquid crystal display (LCD) and switch control

Fault triggers annunciation on panel, alarm contact closure and
internal recording of failed subsystem

Card Cage Modularity

Easy “slide-in” replacement process

Facilitates ease of service and system configuration

SignalBooster_RescueLine-09092013

30303 Aurora Rd.

Solon, OH 44139

866.695.4569

www.bird-technologies.com

*Contact Factory for these models

High Performance Bandpass Filters

Configured to customer requirements and addresses many specifications
requiring custom passbands

Models available with passbands that range from 3 MHz (NPSPAC with excellent
out-of-band rejection) to 18 MHz for full band coverage

Programmable Gain Setting

Ease of initial configuration via front panel

When used in conjunction with OLC DataLog, simplifies post installation adjustments

SignalBooster_Rescueline800_2012 branding 9/9/2013 10:57 AM Page 2