Bird Technologies 4030 User Manual
Page 3
921-4030
7/13/05
Page 3 of 3
Maintenance
The only maintenance the Bird 4030 requires is occasional battery replacement. To replace the batteries:
Requirement: Three 3 volt Lithium cells, Bird P/N 5-1475-1, or equivalent
1. Hold the 4030 with both hands and “break off” the gold plated battery cup - it is a tight snap fit. Don't
try to pull the battery cup straight off! Do not lose the insulating sleeve that lines the cup.
2. Replace the three cells with their negative sides toward the bottom of the cup. Do note get finger
grease (skin oil) on the cells, the cup bottom, or the contacting spring. Wipe the contact surfaces
carefully with a clean cloth if necessary.
3. Snap the battery cup back on, then rotate it to assure proper seating.
Specifications
Frequency Range
1 – 1000 MHz
Typical Sensitivity (Gain at full)
1 W @ 150 MHz radiated power from a CW
source will cause a full-scale deflection at a
distance of eight feet.
Output Characteristics
Compatible with 30 µA meters
Temperature
Operating
Storage
0 to 50 °C (32 to 122 °F)
–20 to +50 °C (–4 to +122 °F)
Dynamic Range (Gain Control)
30 dB nominal
Battery
Three 3V Lithium-Manganese Dioxide cells
100 hour min. life
Dimensions (excluding antenna)
2” H x 1.7” Dia. max. (51 x 44 mm)
Weight, including batteries
3 oz. (0.85 g) nominal