Statistical power sensor – Bird Technologies 7022-Datasheet User Manual
Page 2
Statistical Power Sensor
7022
Statistical Power Sensor
7022
TIME DOMAIN MODE MEASUREMENT
Peak Envelope Power
Accuracy (up to 500 W)
± 5%
+3.75% outside 15-35°C
Peak Envelope Power up to 500 W
Peak Envelope Power
Accuracy (500 W to 1500 W)
± 11%
+3.75% outside 15-35°C
Burst Average Power
Accuracy (0.25 W to 2 W)
± 7%
+3.75% outside 15-35°C
Burst Average Power
Accuracy (2 W to 500 W)
± 5%
+3.75% outside 15-35°C
Burst Average Power
Accuracy (500 W to 1500 W)
± 11%
+3.75% outside 15-35°C
Pulse measurements All IEEE Std 194 Pulse Parameters
Pulse Off Time
Pulse Width
Pulse fall-time
Pulse repetition frequency
Pulse rise time
Pulse period
Pulse duty cycle
Peak power
Pulse overshoot
Triggers Auto
Free Run
Marker Based (Video Trigger)
External
Trigger Hold Off
GENERAL SENSOR CHARACTERISTICS
Measurement Type Thru-Line Power
Frequency Range 350 MHz to 6 GHz
Frequency Measurement
accuracy
± 3MHz with CW signals
Power Measurement
Range
0.25 W to 500 W average, Average Power
Rating limited by Chart below
Dynamic Range 33 dB
Peak to Average Ratio 12 dB, absolute peak power limited to 1500 W
Impedance, Nominal 50 Ohms
Insertion Loss, Max 0.05 dB
Insertion VSWR, Max 1.065 350 - 2500 MHz
1.12, 2500 - 6000 MHz
RF Connectors N Female
Directivity, Min <-30 dB, 350 - 3000 MHz,
<-28dB, 3000 - 6000 MHz
Factory Calibration NIST Traceable
Field Calibration No Field Calibration Required
Data Logging Yes, with the VPM3 software
Interface USB 2.0 Type B (USBTMC)
Power Supply USB Port
STATISTICAL MODE
Peak-to-Average Ratio
(Horizontal Axis)
0 to 16 dB
Percent Time Above
Average Power
(Vertical Axis)
.0001 to 100% (log display)
Number of samples* 268 M samples max
Elapsed Time* 6.5 Seconds max
Confidence Band* 85-99.99 adjustable
Modes on full buffer Re-start
Stop
AVERAGE MODE
Average Forward
Power Range
0.25 W to 500 W
Average Forward
Power Accuracy
4% of Reading ± 16 mW
+3% outside 15-35°C
Average Reflected
Power Range
0.025 W to 50 W
Average Reflected
Power Accuracy
4% of Reading ± 1.6 mW
+3% outside 15-35°C
Return Loss 0 to 23 dB
VSWR 1.15 to 99.9
Rho 0.07 to 1.0
*Number of samples, Elapsed Time and Confidence Band are all related,
if one is set the other two parameters are calculated.
Sample Rate 44 M Samples/s Max
Time Resolution 50nSec to 10 Sec
Time Base Accuracy .01%
Display Refresh Rate 10 times/ sec
(Limited by communication)
Video Bandwidth Settable: 20 MHz (none),
5 MHz, 400 kHz, 4.5 kHz
Points per screen 1001
Trigger input connector BNC female
(1MΩ Impedance; 3V High, 1.2V Low)
Operating Temperature –10 to +50 °C (+14 to +122 °F)
Storage Temperature –40 to +80 °C (–40 to +176 °F)
Humidity, Max 95% maximum
(non-condensing)
Altitude, Max 15,000 ft. (4,500 m)
Dimensions, Nominal 5.9” x 4.8” x 1.3”
(150 mm x 122 mm x 33 mm)
Weight, Max 1.5 lbs.
Mechanical Shock
and Vibration
IAW MIL-PRF-28800F class 3
Certifications EMC Directive (2004/108/EC) European
Standard: EN 61326—
Electrical Equipment for measurement,
control and laboratory use; EMC
Requirements
Test Spec (for radiated immunity):
EN 61000-4-3—Testing and
measurement techniques - 10V/meter
CE Mark
RoHS
STANDARD ACCESSORIES
5A2653-6L USB SeaLatch™ Cable
VPM3 Virtual Power Meter
920-7022 Manual for Statistical Power Sensor
920-VPM3 Manual for Virtual Power Meter
5A2918-11-6 BNC / BNC Trigger Cable
OPTIONAL ACCESSORIES
PTA-MNMN Precision Test Adapter, Male N to Male N
PTA-MNME Precision Test Adapter,
Male N to Male 7/16 (DIN)
PTA-MNFE Precision Test Adapter,
Male N to Female 7/16 (DIN)
PowerSensor_Stasticatical 7022_2012 branding 10/20/2014 1:09 PM Page 3