Statistical Power Sensor

7022

Statistical Power Sensor

7022

TIME DOMAIN MODE MEASUREMENT

Peak Envelope Power

Accuracy (up to 500 W)

± 5%
+3.75% outside 15-35°C

Peak Envelope Power up to 500 W

Peak Envelope Power

Accuracy (500 W to 1500 W)

± 11%
+3.75% outside 15-35°C

Burst Average Power

Accuracy (0.25 W to 2 W)

± 7%
+3.75% outside 15-35°C

Burst Average Power

Accuracy (2 W to 500 W)

± 5%
+3.75% outside 15-35°C

Burst Average Power

Accuracy (500 W to 1500 W)

± 11%
+3.75% outside 15-35°C

Pulse measurements All IEEE Std 194 Pulse Parameters

Pulse Off Time
Pulse Width
Pulse fall-time
Pulse repetition frequency
Pulse rise time
Pulse period
Pulse duty cycle
Peak power
Pulse overshoot

Triggers Auto

Free Run
Marker Based (Video Trigger)
External
Trigger Hold Off

GENERAL SENSOR CHARACTERISTICS

Measurement Type Thru-Line Power

Frequency Range 350 MHz to 6 GHz

Frequency Measurement

accuracy

± 3MHz with CW signals

Power Measurement

Range

0.25 W to 500 W average, Average Power
Rating limited by Chart below

Dynamic Range 33 dB

Peak to Average Ratio 12 dB, absolute peak power limited to 1500 W

Impedance, Nominal 50 Ohms

Insertion Loss, Max 0.05 dB

Insertion VSWR, Max 1.065 350 - 2500 MHz

1.12, 2500 - 6000 MHz

RF Connectors N Female

Directivity, Min <-30 dB, 350 - 3000 MHz,

<-28dB, 3000 - 6000 MHz

Factory Calibration NIST Traceable

Field Calibration No Field Calibration Required

Data Logging Yes, with the VPM3 software

Interface USB 2.0 Type B (USBTMC)

Power Supply USB Port

STATISTICAL MODE

Peak-to-Average Ratio

(Horizontal Axis)

0 to 16 dB

Percent Time Above

Average Power

(Vertical Axis)

.0001 to 100% (log display)

Number of samples* 268 M samples max

Elapsed Time* 6.5 Seconds max

Confidence Band* 85-99.99 adjustable

Modes on full buffer Re-start

Stop

AVERAGE MODE

Average Forward

Power Range

0.25 W to 500 W

Average Forward

Power Accuracy

4% of Reading ± 16 mW
+3% outside 15-35°C

Average Reflected

Power Range

0.025 W to 50 W

Average Reflected

Power Accuracy

4% of Reading ± 1.6 mW
+3% outside 15-35°C

Return Loss 0 to 23 dB

VSWR 1.15 to 99.9

Rho 0.07 to 1.0

*Number of samples, Elapsed Time and Confidence Band are all related,
if one is set the other two parameters are calculated.

Sample Rate 44 M Samples/s Max

Time Resolution 50nSec to 10 Sec

Time Base Accuracy .01%

Display Refresh Rate 10 times/ sec

(Limited by communication)

Video Bandwidth Settable: 20 MHz (none),

5 MHz, 400 kHz, 4.5 kHz

Points per screen 1001

Trigger input connector BNC female

(1MΩ Impedance; 3V High, 1.2V Low)

Operating Temperature –10 to +50 °C (+14 to +122 °F)

Storage Temperature –40 to +80 °C (–40 to +176 °F)

Humidity, Max 95% maximum

(non-condensing)

Altitude, Max 15,000 ft. (4,500 m)

Dimensions, Nominal 5.9” x 4.8” x 1.3”

(150 mm x 122 mm x 33 mm)

Weight, Max 1.5 lbs.

Mechanical Shock

and Vibration

IAW MIL-PRF-28800F class 3

Certifications EMC Directive (2004/108/EC) European

Standard: EN 61326—
Electrical Equipment for measurement,
control and laboratory use; EMC
Requirements

Test Spec (for radiated immunity):
EN 61000-4-3—Testing and
measurement techniques - 10V/meter

CE Mark

RoHS

STANDARD ACCESSORIES

5A2653-6L USB SeaLatch™ Cable

VPM3 Virtual Power Meter

920-7022 Manual for Statistical Power Sensor

920-VPM3 Manual for Virtual Power Meter

5A2918-11-6 BNC / BNC Trigger Cable

OPTIONAL ACCESSORIES

PTA-MNMN Precision Test Adapter, Male N to Male N

PTA-MNME Precision Test Adapter,

Male N to Male 7/16 (DIN)

PTA-MNFE Precision Test Adapter,

Male N to Female 7/16 (DIN)

PowerSensor_Stasticatical 7022_2012 branding 10/20/2014 1:09 PM Page 3