beautypg.com

Bird Technologies 4028 Series-Manual User Manual

Page 4

background image

2

Calibration Frequencies,
Typical (MHz)

*

4028A250K

4028A400K

4028A2M

4028A3M

4028A4M

4028A10M

4028A25M

4028B10M

4028C10M

*. Other calibration frequencies available upon request

0.25, 0.40

0.40

1.8, 2.0, 2.17

2.5, 3.2, 3.5

3.5, 4.0

10.0, 13.56, 15.0

25.76, 27.12, 28.48

10.0, 13.56, 15.0

10.0, 13.56, 15.0

Calibration Power, Typical

1.7 kW

Calibration Technique

Frequency-specific calibration factors stored
in nonvolatile memory in each sensor.
Sensor output corrected for frequency and
temperature within specified ranges.

Calibration Cycle, Nominal

1 year

Sampling Rate, Nominal

2 readings / second

Operating Power

Supplied by power meter via sensor cable

Connectors

4028B10M

4028C10M

All other models

1-5/8” EIA Flanged

3-1/8” EIA Flanged

Customer specified from 7-16 DIN, LC, HN,
and 7/8" flanged, appropriate for frequency
and power.

CE

CE Compliant. Refer to Declaration of
Conformity for specific standards.

Humidity, Max.

95% (Non-condensing)

Altitude, Max.

10,000 feet (3,000 m)

Temperature Range

Operating

Storage

0 to 50 °C (32 to 122 °F)

–20 to +70 °C (–4 to +158 °F)

Dimensions

4028B10M, 4028C10M

All other models

6.75”L x 3.5”W x 4.75”H

(175 x 89 x 121 mm)

4.7”L x 3.2”W x 3.8”H

(120 x 82 x 97mm)

Weight, Nominal
4028B10M, 4028C10M

4028A250K, 400K

All other models

5 lb. 2 oz. (2.33 kg)

1 lb. 13 oz. (0.8 kg)

3 lb. 9 oz. (1.6 kg)