beautypg.com

Calibration carts, Scc7 series, Characteristics – Bird Technologies SCC7 Series-Datasheet User Manual

Page 2: 4027a series power sensor, 4020 series power sensor, Ultra-stable sc13 loads, High power loads

background image

CHARACTERISTICS

Power Levels 1, 2.5, 5, 10 kW

Meter 4421

Sensor Options 4020 Series or 4027A Series (See Below)

Load Options 8251, 8890-300, 8921, 8931-115, 8931-230

(See Below)

Impedance 50 Ohm

Frequency Range 4020

Sensor

100 KHz - 1000 MHz

Frequency Range 4027A

Sensor

250 KHz - 65 MHz

Accuracy 4020 Series ±3% across power and frequency range

Accuracy 4027A Series ±1% at calibration frequency and power

levels
±2% over remainder of power range, and
at other than calibration frequencies

Casters 4 locking swivel

Connector Type *Customer Specified

Operating Position Vertical only

Power Requirements 115/230 VAC, ±10%, 50/60 Hz

Ambient Temp Range 0° to 45°C (For 10kW 0°C to +40°C)

Storage Temperature -20°C to +70°C

Humidity 85% Max., Non condensing

Altitude Load derated above 5,000 feet

5kW & 10kW

Size/Weight

52” L x 20” W x 42” H / 250 lbs.
Fully assembled

1kW & 2.5kW

Size/Weight

42” L x 20” W x 42” H / 175 lbs.
Fully assembled

Material of Construction Stainless steel cart

Applicable Standards CE

CalibrationCart_SCC7-09062012

30303 Aurora Rd.

Solon, OH 44139

866.695.4569

www.bird-technologies.com

Calibration Carts

SCC7 Series

4027A Series Power Sensor

Model

Frequency Range

Power Input

4027A250k

250-400 kHz

3 W to 10 kW

4027A400k

400-550 kHz

3 W to 10 kW

4027A800k

800-950 kHz

3 W to 10 kW

4027A2M

1.5-2.5 MHz

3 W to 10 kW

4027A4M

3-5 MHz

3 W to 10 kW

4027A10M

10-15 MHz

3 W to 10 kW

4027A12M

10-15 MHz

300 mW to 1 kW

4027A25M

25-30 MHz

3 W to 9 kW

4027A35M

35-45 MHz

3 W to 7.5 kW

4027A60M

45-65 MHz

3 W to 6 kW

4027A100M

95-105 MHz

3 W to 4 kW

4027A150M

150-170 MHz

3.75 W to 3.75 kW

4020 SERIES POWER SENSOR

Model

Frequency Range

Power Input

4021

1.8-32 MHz

300 mW to 1 kW at 1.2 kW max

4022

25-1000 MHz

300 mW to 1 kW at 1.2 kW max

4024

1.5-32 MHz

3 W to 10 kW at 1.2 kW max

4025

100-2500 kHz

3 W to 10 kW at 1.2 kW max

* For connector options, please refer to our catalog or contact sales at
866.695.4569 or [email protected]

ULTRA-STABLE SC13 LOADS

Model

Frequency Range & VSWR Power Input

8865SC13

DC to 28 MHz at 1.1 max.
(VSWR less than 1.05:1)

1kW

8890-300SC13

DC to 28 MHz at 1.1 max.
(VSWR less than 1.05:1)

2.5 kW

8921SC13

DC to 28 MHz at 1.1 max.
(VSWR less than 1.05:1)

5 kW

8931-115SC13

DC to 28 MHz at 1.1 max.
(VSWR less than 1.05:1)

10 kW

8931-230SC13

DC to 28 MHz at 1.1 max.
(VSWR less than 1.05:1)

10 kW

HIGH POWER LOADS

Model

Frequency Range & VSWR

Power Input

8251

DC to 1 GHz at 1.1 max.

1000 W continuous

8890-300

DC to 1 GHz at 1.1 max.
1 GHz to 2 GHz at 1.25 max.
2 GHz to 2.4 Ghz at 1.3 max.

2500 W continuous

8921

DC to 1 Ghz at 1.1 max.

5000 W continuous

8931-115

DC to 400 MHz at 1.15 max.
400 MHz to 1 GHz at 1.20 max.

10 kW continuous w/
blower on
2.5 kW continuous w/
blower off

8931-230

DC to 400 MHz at 1.15 max.
400 MHz to 1 Ghz at 1.20 max.

10 kW continuous w/
blower on
2.5 kW continuous w/
blower off