0 start up, 0 setup – Baumfolder Flexifold: 1st Station (from 2005) User Manual
Page 28
PAGE 28
TP10494A
9.0 START UP
When power is applied, the system will first test all
LEDs, memory and display characters for 3 seconds.
After the self diagnostic phase, the display will show
the version number for 3 seconds.
If there are no error messages the display will go
to the jam detector screen if one of the jam detectors is
disabled. If none are disabled or after depressing enter, the
display will go to the initialization screen.
The initialization screen will remain for 10 seconds.
If the “+” button is not pressed during this time no initial-
ization will occur. The display will go to the count screen.
If there is any question about folding accuracy, re-
initialize the system.
LEDs in the memory, or the fold type buttons will
light to indicate the last setting.
10.0 SETUP
WARNING
When adjusting fold lengths on
the fold pans using the keypad, the pans
will move automatically. Be sure to keep
hands away from fold pans when
adjusting fold lengths. It is recommended
that all guards be closed when adjusting
fold lengths.
Important note:
The operator control panel contains a numerical
keypad, which is automatically activated when a function
requires numerical data. The operator panel is color coded
to show this relationship. Numerical data is required for
Sheet length and
Batch Size
Two pieces of information are required to setup a
job, assuming that initialization has previously been
accomplished; sheet length and fold type. Either order may
be used. Select the fold type first or the sheet length first
10.1 Setup for a standard fold
Method 1: Picking fold type first:
To setup for a new fold, press a fold type button. For
example, to set a “Z” fold, press the ”Z” fold button. The
display will show the last job sheet length. If the sheet
length is not correct, you will have 5 seconds to begin
keying in the new sheet length and press the “ENTER”
button (see figure 1). If the sheet length is correct, you may
press the “ENTER” button and not wait 5 seconds before
proceeding.
814MF
VERSION ****
FEEDER JAM DISABLED
INITIALIZATION
(+) YES (-) NO
TOTAL COUNT #######
BATCH ### #####
I I I I I I I I I I I I I I I I I
I I I I I I I I I I I I I I I I I
SELECT FOLD
SHEET LENGTH ##.##