2 run time fault messages – Baumfolder BAUM20: Pile Folder 1st Station (in 2005) User Manual
Page 35
PAGE 35 TP10243-3
6.2 Run Time Fault Messages
Run time fault messages are only displayed when the unit is in Run mode. Fault errors can still occur, but the corresponding
fault message will not be displayed until the unit is switched to Run mode. Run time fault messages are PLC System Errors
or errors in the whole Electric System. It is necessary to call a technician or service.
ENGLISH
GERMAN
CODES
TYPE
DESCRIPTION
DCT X.X.X
DCT X.X.X
DCT X.X.X Information
This is the Software-Version(X.X.X)
Note: do not push any buttons until this message has been
cleared from the display
K5 Relay
K5 Relay
Error 7
PLC System
The drive stop relay, K5, is not responding to the controller.
Error
Action: Call service.
Button
Taste
Error 8
Electrical
A push button is in the wrong state during the version message
System
display. Action: Check Buttons & Cycle Power. If error
Error
persists call service.
Watchdog
Watchdog
Error 9
PLC System
The Watchdog Timer has elapsed without being serviced.
Error
Action: Cycle Power. If error persists call service.
No Tach
Impuls
Error10
Electrical
The Machine Tachometer is reading a velocity outside of the
System
range 10 – 230 meters per minute, while the main drive should
Error
be running. Action: Check the electric. If error persists call
service.
Overload
Uberlast
Error11
Electrical
A Thermal Overload has been tripped.
System
Action: Check the electric. If error persists call service.
Error
Pile Err
Spg.Uber
Error12
Electrical
The Pile Safety Relay is stuck on or there is no power supply to
System
the pile circuits. Action: Check the condition of Relay 1 (K1),
Error
Fuses F1 and F2, and X18, then cycle Power. If error persists
call service.
Overrun
Uberlauf
Error13
Electrical
The Pile Table has moved past its safety stops. Action: Check
System
the limit switches, pile table, and wiring. If error persists call
Error
service.
2
nd
Stat
2Station
Error14
Electrical
The Emergency Stop, Wrong Sheet, and Thermal Overload
System
sense circuits are all indicating failure. Likely cause is Second
Error
Station connector problems. Action: Check the Second Station
Connector, connector X22, and each individual circuit. If error
persists call service.
Suction
Saugtakt
Error15
Electrical
Short circuit on Suction controller. Action: Check the electrics.
System
If error persists call service.
Error
Table 17. Run Time Fault Messages