Diagnostic Messages

(continued)

Message Meaning

Temperature unknown.

Standby Mode has been activated by pressing
a button combination on the user panel.

The spa is operating in Standard Mode.

The spa is operating in Economy Mode.

The spa is operating in
Standard-in-Economy Mode.

Sleep Mode has been activated by pressing a
button combination on the user panel.

pH is low.

pH is high.

Sanitizer is low.

Sanitizer is high.

The pump is on during Standby Mode to
assist in draining the spa.

Hardware failure.

Hardware failure.

Firmware install problem.

Configuration error. Spa cannot start up.

Spa could not trip GFCI.

A pump appears to be stuck on, causing the
water temperature to creep up, possibly to
hazardous levels.

A pump appears to have been stuck on the
last time spa was powered.

Action Required

After the pump has been running for 1 minute, the
temperature will be displayed.

Press any button, except “Jets”, to leave Standby Mode
and return to normal operation.

Temperature display is current after pump has been
running for at least 2 minutes.

” will appear solid on the display when the

temperature is not current. “

” will alternate with the

temperature when the temperature is current.

Operates the same as Standard mode, then reverts to
Economy mode after 1 hour. Press “Temp” followed by
“Light” to switch directly to Economy mode.

” will appear solid on the display when the

temperature is not current. “

” will alternate with the

temperature when the temperature is current.

Add pH increaser according to
manufacturer’s instructions.

Add pH reducer according to manufacturer’s instructions.

Add sanitizer according to manufacturer’s instructions.

Remove spa cover and allow sanitizer to dissipate.

Press “Jets” to turn off the pump when water has drained
(or power off the spa.)

Contact your dealer or service organization.

Contact your dealer or service organization if message
appears on more than one power up.

Contact your dealer or service organization if message
appears on more than one power up.

Contact your dealer or service organization.

Contact your dealer or service organization. Continued
operation may be unsafe.

POWER DOWN SPA IMMEDIATELY. DO NOT ENTER
THE WATER. Contact your dealer or service organization.

POWER DOWN SPA IMMEDIATELY. DO NOT ENTER
THE WATER. Contact your dealer or service organization.