Dimensions, Dimensions (in.) – Bryant Air Conditoner 533A User Manual
Page 2

—2—
DIMENSIONS
A
SQ
AIR IN
AIR IN
3
/
8
-IN.
DIA
TIEDO
WN
KNOCK
OUTS
(2) PLA
CES
H
G
F
E
L
K
J
AIR IN
M
N
AIR DISCHARGE
AIR IN
AIR DISCHARGE
NO
TES:
1.
ALLO
W 30" CLEARANCE
T
O SER
VICE SIDE OF UNIT
, 48" ABO
VE UNIT
, 6" ON ONE
SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PR
OPER AIRFLO
W
.
2.
MINIMUM OUTDOOR OPERA
TING AMBIENT IN COOLING MODE IS 55
°
F, MAX.
125
°
F.
3.
SERIES DESIGNA
TION IS
THE 14TH POSITION OF
THE UNIT MODEL NUMBER.
4.
CENTER OF GRA
VITY .
AIR DISCHARGE
B
P
C
2
7
/
8
"
1
1
/
4
"
FIELD CONTR
OL SUPPL
Y
CONN
7
/
8
-
IN.
DIA
HOLE
FIELD PO
WER SUPPL
Y CONN
7
/
8
-
IN.
DIA HOLE
WITH
1
1
/
8
-
IN.
DIA KNOCK
OUT
AND 1
3
/
8
-
IN.
DIA
KNOCK
OUT
3
/
8
-
IN.
DIA LIQ
UID
LINE CONN
D
DIA
V
APOR LINE CONN
A00015
DIMENSIONS (IN.)
UNIT
SIZE
SERIES
UNIT DIMENSIONS
MINIMUM
MOUNTING
P
AD
DIMENSIONS
ABCD
E
F
G
H
J
K
LM
N
P
024
A
22-1/2
31-15/16
3-3/16
5/8
3-11/16
18-1/8
19-3/4
22-1/4
14-3/8
19-9/16
22-1/16
10-1/4
9-1/2
11-5/8
22-1/2 x 22-1/2
030
A
22-1/2
29-15/16
3-3/16
3/4
3-11/16
18-1/8
19-3/4
22-1/4
14-3/8
19-9/16
22-1/16
10-1/4
9-1/2
11-1/2
22-1/2 x 22-1/2
036
A
22-1/2
33-15/16
3-3/16
3/4
3-11/16
18-1/8
19-3/4
22-1/4
14-3/8
19-9/16
22-1/16
10-1/4
9-1/2
15-1/2
22-1/2 x 22-1/2
042
A
3
0
27-15/16
3-1/4
7/8
6-1/2
23-1/2
27-1/4
29-3/4
20
27-1/16
29-9/16
15
13
14-1/2
30 x 30
048
A
3
0
27-15/16
3-1/4
7/8
6-1/2
23-1/2
27-1/4
29-3/4
20
27-1/16
29-9/16
15
13
14-1/2
30 x 30
060
A
3
0
39-15/16
3-1/4
7/8
6-1/2
23-1/2
27-1/4
29-3/4
20
27-1/16
29-9/16
15-1/2
14-3/4
14-1/2
30 x 30