Weidmuller WI GTWY-9: Wireless Gateways v1.2 User Manual
Wi-gtwy-9, Installation guide, Aerial installation

Weidmuller Inc., v1.2
WI-GTWY-9
Installation Guide
FCC Notice
This device complies with Part 15.247 of the FCC Rules.
Operation is subject to the following two conditions:
1) This device may not cause harmful interference and
2) This device must accept any interference received, including
interference that may cause undesired operation
Aerial Installation
WI-GTWY-9 Installation
Power supply: (A) 12-24VAC 16VA CSA Certified Class 2
(B) 9-30VDC 16VA CSA Certified Class 2
(C) 13.8V Lead Acid Battery or Gel-cell
Choose option and wire as shown
Host Protocol Connection
Digital Input
Voltage Free
Contact
OR
Transistor
Device
1m minimum
COLINEAR
ANTENNA
MAST
EARTH STAKE
IF GROUND CONDITIONS ARE
POOR, INSTALL MORE THAN
INSTALL AERIAL ABOVE
LOCAL OBSTRUCTIONS
ANT
WI-
GTWY
SURGE
ARRESTOR
(OPTIONAL)
COAXIAL CABLE
WEATHERPROOF
CONNECTORS WITH
“3M 23” TAPE
STRESS RELIEF LOOP
PROVIDE GOOD
GROUND
CONNECTION TO
MAST, MODULE
AND SURGE
ARRESTOR
GND
ANTENNA INSTALLATION
Antennas should be installed by experienced contractors.
WIRELESS GATEWAY
S
U
P
1
S
U
P
2
G
N
D
B
A
T+
G
N
D
D
IO
8
D
IO
7
D
IO
6
D
IO
5
D
IO
4
D
IO
3
D
IO
2
D
IO
1
G
N
D
- +
To Earth
Connection
DC Supply
9-30VDC
16VA
S
U
P
2
S
U
P
1
AC Supply 12-24VAC
Do not earth SUP1 or
SUP2 connections
2A
+
-
Optional 12V
Backup Battery up
to 100 Amphour
+ -
Digital Output
Max 30VDC, 500mA
DC Relay Supply
NOTES
1. DIO channels can be
wired as either inputs or
outputs.
2. All I/O must be SELV.
CAUTION!
For continued
protection against
risk of fire, replace
the module fuse only
with the same type
and rating
WARNING !
EXPLOSION HAZARD
DO NOT DISCONNECT
WHILE CIRCUIT IS LIVE
UNLESS AREA IS
KNOWN TO BE NON
HAZARDOUS
WI-GTWY-9-xx
To Earth
Connection
S
U
P
1
S
U
P
2
G
N
D
ONE EARTH STAKE