Product operation, Specifications – Weidmuller EBR-Module RS232 - Industrial Ethernet External Backup and Restore Module User Manual
Page 4

Product Operation
Save the switch’s configuration on the EBR-Module-RS232
Use the switch’s web console to save the switches configuration to the
EBR-Module-RS232. The function is found under “Basic Settings/System File
Upgrade/Backup Media” in the web console.
Load the configuration from the EBR-Module-RS232 to the switch
There are 2 ways to load the configuration from the EBR-Module-RS232 to a
Weidmüller managed Ethernet Switch:
1. Load Automatically
When the EBR-Module-RS232 is plugged in, the switch will automatically
load the configuration from the EBR-Module-RS232 after the switch reboots.
This function can be disabled through the web console under “Basic
Settings/System File Upgrade/Backup Media”, or through the telnet console
under “Basic Settings/Backup Media”.
2. Load Manually
When the EBR-Module-RS232 is plugged in, the configuration can be loaded
manually through the switch’s web console under “Basic Settings/System
File Upgrade/Backup Media”.
NOTE For further details on operation with EBR-Module-RS232 through
the switch’s web console, please refer to the user’s manual of the
used switch.
NOTE The status of the EBR-Module-RS232 may be checked on the
switch’s web console or by observing the switch’s front panel LEDs.
Operation
Switch’s LED status
Save/Load in
progress
FAULT, MASTER, COUPLER LEDs
blink sequentially and circularly
Save/Load successful
FAULT, MASTER, COUPLER LEDs
light off
Save/Load failed
FAULT LED light on, MASTER and
COUPLE LEDs light off
Specifications
Connectors
RS-232 RJ45 port
Power Requirement
3 to 5 VDC, power input via RS-232 RTS
Configuration
via Weidmüller managed Ethernet Switch’s web
console
Casing
PVC molding, IP40
Weight
50 g
Installation
M4 screw (> 4 mm)
Dimension (W × D × H)
32.5 Ч 97 Ч 12 mm
- 4 -