SECTION 9
Product Selection Guide 120V
PRODUCT CODE
Heating
Cable
Length
Power
Total
Resistance
in Ω @20°C
(68ºF)
Current
3-inch Spacing
4-inch Spacing
Total Cable
Coverage
(sq. ft.)*
Total No.
of Cable
Guides
(rounded)
Watts
per
Square
Foot
Total Cable
Coverage
(sq. ft.)*
Total No. of
Cable Guides
(rounded)
Watts per
Square
Foot
Feet
Watts
Nom
Amps
TCT120-3W-030
30
90
160.00
0.75
9
9
10
12
12
8
TCT120-3W-040
40
120
120.00
1.00
11
12
11
15
12
8
TCT120-3W-050
50
150
96.00
1.25
14
12
11
19
20
8
TCT120-3W-070
70
210
68.57
1.75
19
20
11
25
20
8
TCT120-3W-090
90
270
53.33
2.25
25
20
11
32
24
8
TCT120-3W-120
120
360
40.00
3.00
32
24
11
43
35
8
TCT120-3W-150
150
450
32.00
3.75
40
35
11
53
40
8
TCT120-3W-180
180
540
26.67
4.50
48
35
11
63
48
9
TCT120-3W-220
220
660
21.82
5.50
58
48
11
77
54
9
TCT120-3W-260
260
780
18.46
6.50
68
54
11
90
70
9
TCT120-3W-300
300
900
16.00
7.50
78
54
12
104
77
9
TCT120-3W-340
340
1020
14.12
8.50
89
70
11
117
88
9
TCT120-3W-375
375
1125
12.80
9.38
97
70
12
129
96
9
TCT120-3W-432
432
1296
11.11
10.80
112
77
12
148
104
9
TCT120-3W-468
468
1404
10.26
11.70
121
88
12
161
117
9
*Based on a square room with an unheated border of 3 inches