Installation – Regency Horizon HZ54EPV Large Gas Fireplace User Manual
Page 49
Regency Horizon HZ54EPV Gas Fireplace
49
INSTALLATION
12)
Secure the fan to the fl oor of the unit with 2 screws.
*See wiring diagram in manual.
13)
Attach the ground wire from the fan to the ground lug in the unit. The
ground lug is located just in front of the receptacle box on the left
side on the fl oor of the unit. Plug fan
If installing a GTMF system - go to step 20 before proceeding.
14)
Slide the thermodisc into the bracket on the bottom side of the fan
access panel - check fan access panel gasket - replace if necessary.
Ground Lug
10)
Remove 8 screws to remove the fan access panel cover - located on
the left hand side fl oor of the fi rebox.
11)
Manoeuvre the fan into position on the fl oor of the unit. Tilt the fan
to get through the fan access panel and into position.
Fan Access Panel
8) After extenders have been removed. Remove the 2 screws that
secure the burner tray, at the base of the fi rebox.
9)
Slide the burner to the left and lift it out.
Location of screws securing burner
6) Loosen 6 screws that secure the burner extenders. on burner tray,
located behind the burner on either side of the pilot assembly.
7)
Lift out the 2 burner tray extenders.
Burner tray extenders
Burner tray extenders
Burner tray