beautypg.com

Safety label, Duplicate s/n – Regency Panorama P131 Three Sided Gas Fireplace User Manual

Page 5

background image

Regency

®

P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

5

SAFETY LABEL

This is a copy of the label that accompanies
each P121-2/P121LC-2/P121RC-2/P131-2
Zero Clearance Direct Vent Gas Fireplace.
We have printed a copy of the contents here
for your review. The safety label is located
on the front inside base of the unit, visible
when the bottom louver is open.

NOTE: Regency

®

units are constantly being

improved. Check the label on the unit and
if there is a difference, the label on the unit
is the correct one.

Copy of Safety Decal for P121/P121LC/P121RC/P131

APP

AREIL

FONCTIONNANT

AU

GAZ

P

ROP

ANE

CONCU

POUR

ETRE

POELE:

Pression

d'allimentation

minimum

Pression

à

la

tubulure

d

'

c

happement

lev

e

Pression

à

la

tubulure

d

'

c

happement

basse

Grandeur

de

l'injecteur

D

bit

minimum

selon

D

bit

maximum

s

elon

Calorifique

Calorifique

l'altitude

йй

й

й

й

й

DO

NOT

REMOVE

THIS

LABEL

/

N

E

P

AS

ENLEVER

CETTE

ÉTIQUETTE

304

NA

TURAL

GAS:

Minimum

supply

pressure

Manifold

pressure

high

Manifold

pressure

low

Orifice

size

Minimum

input

Maximum

input

Altitude

L

PROP

ANE:

DOOR

SEAL:Please

check

that

the

door

is

p

roperly

sealed

Minimum

Clearances

to

Combustibles

/

Degagement

Minimum

De

Materiaux

Combustibles

T

op,

bottom,

sides

&

rear

of

unit

Min.

39"

(991mm)

"

(0mm)

0"

Clearance

to

combustibles

from:

Mantel

Height

from

Base

of

Unit:

Side

W

all

Clearance

from

Side

Facing

0

Horizontal

T

o

p

2-1/2"

(64mm)

Horizontal

Side

1-1/2"

(38mm)

Horizontal

Bottom

1-1/2"

(38mm)

Minimum

V

ent

Clearances:

Serial

No./

No

de

serie

918-497a

5"

WC

(1.25

kPa)

3.8"

WC

(0.95

kPa)

1.1"

WC

(0.27

kPa)

#

3

1

DMS

20,500

Btu/h

(6.01

kW)

0-4500

ft/pi

(0-1372

m)

40,000

Btu/h

(1

1.72

kW)

12"

WC

(3.00

kPa)

1

1

"

W

C

(2.74

kPa)

2.9"

WC

(0.72

kPa)

#

5

0

DMS

20,600

Btu/h

(6.04

kW)

39,000

Btu/h

(1

1.43

kW)

0-4500

ft/pi

(0-1372

m)

APP

AREIL

FONCTIONNANT

AU

NA

TURAL

GAZ

CONCU

POUR

ETRE

POELE:

Pression

d'allimentation

minimum

Pression

à

la

tubulure

d

'

c

happement

lev

e

Pression

à

la

tubulure

d

'

c

happement

basse

Grandeur

de

l'injecteur

D

bit

minimum

selon

D

bit

maximum

s

elon

l'altitude

Calorifique

Calorifique

йй

й

й

й

й

Listed:

Certified

for/Certifi

e

pour:

T

ested

to:

VENTED

GAS

FIREPLACE

HEA

TER/

CANADA

and

U.S.A.

Gas-Fired

Appliances

For

Use

At

High

Altitudes

FOYER

AU

GAZ

А

Й

V

ACUA

TION

é

WN#

16474

CAN/CGA-2.17-M91,

V

ented

Gas

Fireplace

Heaters

ANSI

Z21.88a-2007/CSA

2.33a-2007

Made

in

Canada/

Fabrique

au

Canada

Duplicate

S/N

(See

Instruction

Manual

for

Detailed

Instructions)

P121LC-NG2

P121LC-LP2

P121RC-NG2

P121RC-LP2

P121-NG2

P121-LP2

Model:

Modele:

P131-NG2

P131-LP2

304

Model/Modele:

P121-LP2,

P131-LP2,

P121LC-LP2,

P121RC-LP2

Model/Modele:

P121-NG2,

P131-NG2,

P121LC-NG2,

P121RC-NG2

Minimum

supply

pressure

Manifold

pressure

high

Manifold

pressure

low

Orifice

size

Minimum

input

Maximum

input

Altitude

This

appliance

must

be

installed

in

accordance

with

local

codes,

if

any;

if

none,

follow

the

National

Fuel

Gas

Code,

ANSI

Z223.1,

or

Natural

Gas

and

Propane

Installation

Code,

CSA

B149.1.

This

appliance

must

be

installed

in

accordance

with

the

Standard

CAN/CSA

Z240

MH,

Mobile

Housing,

in

Canada,

or

with

the

Manufactured

Home

Construction

and

Safety

Standard,

T

itle

24

CFR,

Part

3280,

in

the

United

States,

or

when

such

a

standard

is

not

applicable,

ANSI/NCSBCS

A225.1/NFP

A

501A,

Manufactured

Home

Installations

Standard

or

ANSI

A1

19.2

ou

NFP

A

501C

Standard

for

Recreational

V

ehicles

This

appliance

is

only

for

use

with

the

type

of

gas

indicated

on

the

rating

plate

and

may

be

installed

in

an

aftermarket,

permanently

located,

manufactured

(mobile)

home

where

not

prohibited

by

local

codes.

See

owner's

manual

for

details.

Installer

l'appareil

selon

les

codes

ou

règlements

locaux,

ou,

en

l'absence

de

tels

règlements,

selon

les

codes

d'installation

ANSI

Z223.1,

National

Fuel

Gas

Code

ou

CSA-B149.1

en

vigueur

.

Installer

l'appareil

selon

la

norme

CAN/CSA-Z240,

Série

MM,

Maison

mobiles

ou

CAN/CSA-Z240

VC,

Véhicules

de

camping,

ou

la

norme

24

CFR

Part

3280,

Manufactured

Home

Construction

and

Safety

Standard.

Si

ces

normes

ne

sont

pas

pertinentes,

utilisez

la

norme

ANSI/NCSBCS

A225.1/NFP

A

501A,

Manufactured

Home

Installations

Standard,

ou

ANSI

A1

19.2

ou

NFP

A

501C

Standard

for

Recreational

V

e

hicles.

For

use

with

glass

doors

certified

with

the

appliance

only

.

This

vented

gas

fireplace

heater

is

not

for

use

with

air

filters.

Ne

pas

utiliser

de

filtre

à

air

avec

ce

foyer

au

gaz

à

évacuation.

Cet

appareil

doit

être

utilize

uniquement

avec

le

type

de

gaz

indiqué

sur

la

plaque

signalétique.

Cet

appareil

peut

être

installé

dans

une

maison

préfabriquée

ou

mobile

(É.-U.

seulement)

installée

à

demeure

si

les

règlements

locaux

le

permettent.

V

oir

la

notice

de

l'utilisateur

pour

plus

de

renseignements.

Cet

appareil

ne

peut

pas

être

utilisé

avec

d'autres

gaz

sauf

si

une

trousse

de

conversion

certifiée

est

fournie.

Pour

utilisation

uniquement

avec

les

portes

en

verre

certifiées

avec

l'appareil.

Electrical

supply

/Élec

trique

1

15V

AC,

1.13

A,

60Hz.

VENTED

GAS

FIREPLACE

HEA

TER

-

NOT

FOR

USE

WITH

SOLID

FUELS.

/

NE

P

A

S

UTILISER

A

VEC

DU

COMBUSTIBLE

SOLIDE.

FOYER

AU

GAZ

А

Й

V

ACUA

TION

-

For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.

For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.

For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.

The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.

This manual is related to the following products: