P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

INSTALLATION

INSTALLATION

CHECKLIST

Note: These units are

non-load bearing.

1) Locate appliance. Refer to the following

sections:

a)

Locating

Your

Fireplace

b)

Clearances

c) Combustible Mantel Clearances

d) Framing & Finishing

e) Venting. See the "Venting Introduction"

to "Venting Arrangements" sections.

2) Assemble Top Standoffs. Refer to the "Unit

Assembly Prior to Installation" section.
(NOTE: must be done before installing
unit into fi replace.)

3) Install vent. See the "Horizontal

Installations" to "Installation Procedures"

sections

4) Make gas connections. Test the pilot. Must

be as per diagram. Refer to the "Gas Line
Installation" & "Pilot Adjustment" sections.

5) Install standard and optional features. Refer

to the following sections where applicable:

a. Log Set

b. Glass Door

c.

Finishing

Trim

d. Louvers & Grills

e. Remote Control

f. Wall Switch

g.

Wall

Thermostat

6) Final

check.

Before leaving this unit with the customer,
the installer must ensure that the appliance is
fi ring correctly and operation fully explained to
customer.

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label 40,000 Btu/h
NG, and 39,000 Btu/h LP) after burning
appliance for 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.

GENERAL SAFETY

INFORMATION

1) The appliance installation must conform with

local codes or, in the absence of local codes,
with the current Canadian or National Gas
Codes, CAN1-B149 or ANSI

Z223.1

Installation Codes.

2) See general construction and assembly

instructions. The appliance and vent should
be enclosed.

3) This appliance must be connected to the

specifi ed vent and termination cap to the outside
of the building envelope. Never vent to another
room or inside a building. Make sure that the
vent is fi tted as per Venting instructions.

4) Inspect the venting system annually for blockage

and any signs of deterioration.

5) Venting terminals shall not be recessed into a

wall or siding.

6) Any safety glass removed for servicing must

be replaced prior to operating the appliance.

7) To prevent injury, do not allow anyone who is

unfamiliar with the operation to use the fi replace.

8) Wear gloves and safety glasses for protection

while doing required maintenance.

9) Be aware of electrical wiring locations in walls

and ceilings when cutting holes for termination.

10) Under no circumstances should this appliance

be modifi ed. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.

11) Installation and any repairs to this appliance

should be done by a qualifi ed service person.
A professional service person should be called
to inspect this appliance annually. Make it a
practice to have all of your gas appliances
checked annually.

12) Do not slam shut or strike the glass door.

13) Under no circumstances should any solid fuels

(wood, paper, cardboard, coal, etc.) be used in
this appliance.

14) The appliance area must be kept clear and

free of combustible materials, (gases and other
fl ammable vapours and liquids).

Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.