L540E-2 / HZI540E-2 Direct Vent Gas Insert

INSTALLATION

GTMF REMOTE SYSTEM - IMPORTANT: The 120V fan control module serves as the power source for this unit. The AA batteries in the

receiver only serve as a backup in case 120 volt power lost within the home.

PROFLAME REMOTE SYSTEM GTMF WITH FAN (L540E / HZI540E)

WIRING DIAGRAM

CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.

Ground

Green

Neutral

Live

Black

Red

Fan Thermodisc

(normally open)

Ground

120V AC

60 Hz

Fan

Black

Black

Red

Black

Proflame System
Configuration
886 GTMF
Wire Diagram

SureFire™ Switch

0.584.907

Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.

Thermostat

(Optional)

See optional wall thermostat
installation in this manual.

885