Installation – Regency Horizon HZ40E Medium Gas Fireplace User Manual
Page 47
![background image](/manuals/573810/47/background.png)
Regency Horizon™ HZ40E-2 Gas Fireplace
47
INSTALLATION
OPTIONAL FAN INSTALLATION - INTO EXISTING INSTALLATIONS
4)
Remove the glass door.
a)
Remove the 3 screws shown below at the bottom of the glass
door
.
b)
Swing the door out 45
o
from the bottom and lift up and out.
Faceplate
(4pc style
shown)
Glass Door
Location of screws on access plate
120 Volt AC power is needed for the fan switch and blower. The fan can be
hard wired if desired. The receptacle box should be installed on the left
hand side of the unit by a qualifi ed electrician. The neutral (wider) slot of the
polarized receptacle should be at the top (see page 41 for wiring diagram).
Unit must be grounded at all times. Do not cut the ground terminal off
under any circumstances.
1)
Shut off the gas and power supply to the unit.
3)
Remove the faceplate or door frame by lifting it up off the glass door.
5)
Remove the inner panels - reverse of "Inner panel Installation" in the
installation
manual.
6)
Remove the burner tray cover by lifting up and out as shown below.
* Prior to removing burner - remove crystals, pebbles, spa stones and inner
panels - if installed.
7)
Loosen 3 screws at the back of the burner to release it.
8)
Remove the burner by sliding it to the right - then lift out.
9)
Remove the left access plate by undoing the 8 screws - see locations
below.
10)
Remove the left access plate by undoing the 8 screws - see locations
below.