beautypg.com

Installation, Framing & finishing – Regency Horizon HZ40E Medium Gas Fireplace User Manual

Page 16

background image

16

Regency Horizon™ HZ40E-2 Gas Fireplace

INSTALLATION

FRAMING & FINISHING

Note: When constructing the framed opening, please ensure there

is access to install the gas lines when the unit is installed.

2) For exterior walls, insulate the enclosure to the same degree as the

rest of the house, apply vapour barrier and drywall, as per local instal-
lation codes. (Do not insulate the fi replace itself.)

WARNING: Failure to insulate and add vapor barriers to the inside
of the exterior wall will result in operational and performance
problems including, but not limited to: excessive condensation
on glass doors, poor fl ame package, carbon, blue fl ames etc.
These are not product related issues.

3) The unit does not have to be completely enclosed in a chase. You

must maintain clearances from the vent to combustible materials: See
"Clearances" section. Combustible materials can be laid against the
side and back standoffs and the stove base.

4) Non-combustible material (ie. tile, slate, etc) may be brought up to and

overlap the unit (top and bottom) ensuring that the maximum thickness
does not go beyond the 1-1/2" as shown in the diagram below. The
faceplate will not be able to be mounted if fi nished material is beyond
1-1/2".

1) Frame in the enclosure for the unit with framing material.

IMPORTANT: The framed opening must be of non-combustible

material.

IMPORTANT: 1/2" gap required between faceplate and fi nished wall when

using 4 pce. Faceplate (Part # 256-924, 256-926, 256-927)

1/2" required
between faceplate
+ fi nished wall

27-5/8"

52-3/4"

5) If material such as brick, stone, etc extends past the faceplate depth (1-1/2"),

when fi nishing around the faceplate, the minimum opening dimensions noted
below must be adhered to ensuring for the removal of the faceplate and for
the safe operation of this appliance.

NOTE: Spacing of 1" around the completed surround must be adhered to.

Unit shown with inner door frame only

Unit shown with inner and outer door frame

Unit shown with 4 piece faceplate

39-13/16”

16-7/8”

47- 1/16”

24-

9/16