Specifications

d

imenSionS

:

figure 2: dimensions of Gci60.

Input rating when using: Wood Pellets/Corn - 55,000BTU (16.1KW•hr) & Wheat/Barley - 53,000BTU (15.5KW•hr).

Table 1: GCI60 Specifications.

Description

Fuel type

Residential Pellet Heater

6mm (¼”) dia. Pellets - wood, corn, wheat, & barley*

Voltage

Current

Max Power

110 - 120 V

4.2 Amps

504 Watts

Frequency

Hopper Capacity

Consumption on Low

60 Hz

up to 60 lb (36.3 Kg)

1.5 lb/hr (0.68 Kg/hr)*

Testing Standard

Weight (with full hopper)

Consumption on High

ASTM 1509-04

370 lb (167.8 Kg)

6.5 lb/hr (2.95 Kg/hr)*

*Note: Consumption will vary with the type and quality of pellets / fuel used.

S

pecificationS

:

33 9⁄16

43 3⁄16

41 7⁄8

16 3⁄8

24 ¾

26 7⁄8

22 15⁄16

11 ¾

12 ¾

Hampton GCI60 Cast Pellet Insert Technical Manual

7