Installation without a masonry fireplace -

The GCI60 can be installed without an existing masonry fireplace by building an enclosure for the unit

to be installed in. This enclosure must be a minimum of 18” deep, 36” wide and 23-1/4” high and made

with ½” noncombustible cement board. The floor of the enclosure must consist of a minimum of 1-1/4”

air space and a layer of ½” noncombustible cement board and a layer of tile. The air space must be

supported with sheet metal studs and have no combustible material in the air space. All venting for

Built-In installation must use PL or L venting and be installed with vent manufacturer’s recommended

clearances. Refer to page 9 for Clearances to Combustibles.