Service manual WM70.C
31
This document must not be copied without
our written pemission, and the contents
thereof must not be imparted to a third party
nor be used for any unauthorized purpose.
Contravention will be prosecuted.
Asko Appliance AB
CIRCUIT DIAGRAM WM70.C HWC
80 931 37 - 00
WIRES IN ALL MACHINES
INTERNAL CONNECTION
RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F)
VALUES WITHIN +/-10% ARE REGARDED AS NORMAL COMPONENT
F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm
EL: HEATING ELEMENT 25 Ohm
AP: DRAIN PUMP 50 Hz 144 Ohm
AP: DRAIN PUMP 60 Hz 76 Ohm
AV: DRAIN VALVE 110/134 Ohm
LL: DOOR LOCK, 1-2 122 Ohm
NTC: THERMISTOR 6.1 - 3.8 K Ohm
IV 1: INLET VALVE 1 3.7 K Ohm
IV 2: INLET VALVE 2 3.7 K Ohm
IV3: INLET VLAVE 3 3.5 K Ohm
MO: MOTOR, 1-3 4,3±7% Ohm
1-2 4,3±7% Ohm
2-3 4,3±7% Ohm
MCU: MOTOR CONTROL UNIT
N: PRESSURE SWITCH
TS: PRESSURE SENSOR
TG: TACHO GENERATOR
BA: CONTAINER
INKB: INCOMING GROUND
CI: COMMUNICATIONS INTERFACE
MV: MAGNETIC VALVE
SV: SWITCHING VALVE
IV2
IV1
NTC
F
TS
AP/AV
LL
MO
MCU
3
2
1
CABLE POSITIONS
1: MOTOR COMMUNICATION
2: THERMISTOR
3: INLET VALVES
4: DOOR LOCK, DRAIN PUMP, PREASSURE SWITCH
6:
COMMUNICATION INTERFACE
7: COIN COLLECTOR
8: POWER
9: HEATING ELEMENT, PREASSURE SWITCH
10: MOTOR POWER
3
1
2
TG
S1
S4 S5
N14 N12 N16 N11 E L1 F31 N R 43 R 44 R 34 R 33 R 23 R 24 R A R B EL INKB BA N L2 L3 L1 R33 R43 E L2 F21 F CM2 F2 F3 CM3 R23 AV BO WIRES IN SOME MACHINES CI PHASE BLACK CM1 CM2 BROWN CM5 CM4 CM3 GROUND BLUE CM6 BLACK BLUE CM1 CM4 CM6 CI F1 F2 F21 F22 F31 F32 N L1 R33 CM2 CM6 F1 F22/32 F2 INKB F21 1 Phase, 10 A 3 Phase, 10A C M 5 2011-11-11 SERVICE MENU TURN OFF POWER (S1) WAIT FOR AT LEAST 5 SEC HOLD S4 TURN ON POWER (S1) PRESS S4 5 TIMES TO ENTER SERVICE MENU PRESS DOOR OPENING (S5) TO CHANGE MENU STEP ROTATE DIAL TO CHANGE IN STEP PRESSING START/STOP (S4) STORES AND EXITS SERVICE MENU USER SETTINGS MENU TURN OFF POWER (S1) WAIT FOR AT LEAST 5 SEC HOLD S5 TURN ON POWER (S1) PRESS S5 5 TIMES TO ENTER MENU YELLOW- GREEN FROM CONTROL UNIT NEUTRAL HEATER FROM CONTROL UNIT If coin meter is selected CM1 and CM4 needs to be closed to start the machine (default closed) CONNECTOR FOR COIN METER N L1 R33 CM2/F21 CM6 F1 F22/32 F2 INKB F31 1 Phase, 16 A MV SV Relay board