beautypg.com

2appliance details – Bosch AQUA STAR 2400E LP User Manual

Page 4

background image

6 720 608 263

4

Appliance details

2

Appliance details

2.1

Features

Parts

• Touch pad interface control

• High power pre-mix compact burner with low NOx

emissions

• Modulating gas valve with constant gas to air ratio

control

• Modulating water valve for improved comfort and

temperature control.

Safety

• Flame sensor (ionization) rod

• Overheat sensor

• Temperature limiter

• Fan speed monitoring.

High quality materials for long working life

• Copper heat exchanger

• High efficiency Ceramat burner

• Compact space saver: mounts on a wall with a

supplied bracket.

• Easily removable one-piece cover.

Features

• LCD Display

• On/Off and temperature control switches

• Reset button

• Program key (selectable temperature)

• Failure codes for easy diagnostics and repair

• Diagnostic mode for troubleshooting/informational

purposes

• Cascading function.

Accessories

• Optional wireless remote control accessory to

remotely set temperature (Part # TSTAT2) .

• Tankless Link: Allows two 2400 E heaters to be

linked together for double the hot water volume (Part
# TLINK) .

• Horizontal vent termination kit (Part # 4TWHVK3S) .

2.2

2400 E Specifications (Technical
data)

Approved in US/Canada

Capacity

Maximum flow rate: 6.35 GPM (24 l/min) at a 45°F
(25°C) rise.

Maximum output

142,968 Btu/h (41.8 kW)

Maximum input

175,000 Btu/h (51.2 kW)

Efficiency in %

Recovery efficiency 86.5%

Min. Output

31,131 Btu/h (9.1 kW)

Temperature Control

Selection range: 100°F (38°C) - 140°F (60°C)

Default temperature: 122°F (50°C)

Stability: +/- 2°F (+/- 1°C)

Gas Requirement

Gas connection (inches) - ¾” NPT

Inlet gas pressure under operation (with a high hot
water flow rate)*

• Propane: 11” - 14” water column

• Natural Gas: 5” - 14” water column.

* To measure gas pressure, see Measuring gas
pressure, chapter 3.8.

Venting

A condensate trap is integrated into the exhaust flue
gas collar of the heater, the supplied condensate drain
tube MUST be installed to it for proper removal of
condensate from the trap. Additional condensate traps
and drains may be necessary; see chapter 3.6 for
Venting.

Water

• Hot water connection (inches) - ¾” NPT

• Cold water connection (inches) - ¾” NPT

• Water valve material: Polymer (PPS) (Polypropylene

Sulfid)

• Minimum water flow for activation: 0.8 gallon/minute

(3 l/m)

• Minimum recommended water pressure: 30 PSI

(2.07 bar)

• Connections:

– Bottom of heater

Combustion

• NOx ≤ 55 ppm

• CO ≤ 300 ppm

i

BOSCH is constantly improving its
products, therefore specifications are
subject to change without prior notice.

This manual is related to the following products: