beautypg.com

5 control board diagnostics – Bosch AQUA STAR 2400E LP User Manual

Page 32

background image

6 720 608 263

32

Maintenance and service

5.5

Control board diagnostics

1. Turn on/off switch on water heater to off (O) position.

2. Press and hold the program (

) button while

turning the on/off switch to the on (I) position. The
display will cycle through a startup procedure
including the software version.

3. Release the '

' button when '188' appears on the

display. The display should read 'P2' when the
program button is released. If not, repeat process.

B Press and release the '

' button on the control

panel until the display reads 'P4'. You are now in the
diagnostic mode of the control board.

4. When the display reads 'P4', press and release the

'

' button once again and the display should read

'E'.

B Use the '

' and '

' button on the control board

to cycle through different diagnostic modes
available.

5. Once in the selected diagnostic mode of your

choice, press and release the '

' button to display

the diagnostic information.

EXAMPLE: to read the flow rate in gallons per minute
while the unit is flowing water, cycle to the '3d' mode
and press the '

' button. A reading of 25 on the

display would indicate the heater is reading a flow rate
of 2.5 gallons/minute.

6. Once the information is obtained, press the '

'

button again to return to the diagnostic mode menu
and scroll to addition diagnostic information.

B To exit the diagnostic mode of the heater, use the

'

' or '

' button until the display reads 'E'.

7. Press the '

' button once again and the display

should read P4.

8. Turn the on/off switch off (O) and back on (I) again to

return heater to normal function.

Diagnostic menu

E

Entry/Exit into sub-modes

0d

Set-point temperature

1d

Inlet water temperature (F)

2d

Outlet water temperature (°F)

3d

Water flow (gallons/min)

4d

Gas type (LP or NG)

5d

Fan speed (Hz)

6d

Burner power (%)

7d

Maximum power (kW)

8d

PWM cycle (signal to fan)

9d

Appliance selection

1F

Most recent error/failure

2F

2nd most recent error

3F

3rd most recent error

4F

4th most recent error

5F

5th most recent error

6F

6th most recent error

7F

7th most recent error

8F

8th most recent error

9F

9th most recent error

10F

10th most recent error

Table 11