WEB600 Firmware Revision History

WEB600 Embedded Firmware Feature and Correction Summary

------------------------------------------------------------------------------------------------------------------------------------
NOTE: This document covers both the original WEB600 and the new WEB600 with Relay Output. The
firmware files ARE NOT compatible. Pay careful attention to select the proper file when performing a
firmware update. Contact Sensaphone Technical Support if you have any questions: (877)373-2700 or
[email protected].
------------------------------------------------------------------------------------------------------------------------------------

WEB600 with Relay Output
Version 1.59
(July 15, 2013)

• Corrected issue which prevented the Battery Low Limit from being displayed.

Warning: If you are upgrading from 1.56 or earlier, the Alarm and Table Limits will be off by a
factor of 10 if you reload your programming from a saved programming file. Check your zone
programming and adjust as necessary.

Version 1.58 (July 8, 2013)

• Added support for extended precision when using 4-20mA sensors. Sensors can now read to two

decimal places.

• Enhanced datalogging such that samples are now recorded evenly at fixed times on the hour, minute,

and second. Removed extraneous datalog entries.

• Corrected issue which caused false error messages to appear on the Zone programming screen.
• Enhanced the gauges on the summary screen to account for small values.

Warning: If you are upgrading from 1.56 or earlier, the Alarm and Table Limits will be off by a
factor of 10 if you reload your programming from a saved programming file. Check your zone
programming and adjust as necessary.

Version 1.56 (December 6, 2012)

• Corrected a problem that could cause e-mail messages to fail under certain conditions. When the

unit attempted to send e-mail or perform time synchronization while the network connection
was unavailable, the unit could potentially fail to send e-mail messages - even after the network
connection returned.

• Corrected a scaling problem with the bar gauge when used in manual mode.
• Corrected a problem with SNMP traps.

Version 1.55 (October 24, 2012)

• Changed the web page timing to allow the page to load over slow and/or high latency connections -

such as a cellular or satellite uplink.

• Fixed DHCP to support DHCP relay agents.
• Added Pulse Count as an input type with a programmable coefficient for scaling.
• Removed the ability to change the input order on the Zones page.
• Changed the datalog export function (csv & xml) to include proper zone ID numbers.
• Corrected an issue on the web page where the bar gauge upper and lower limits would not adjust

properly when set to Auto mode.