Acm-1 access control module, Security door controls – SDC FB4DC User Manual
Page 5

P:\INSTALLATION INST\POWER SUPPLY\INST-ACM-1\INST-ACM-1.vsd REV B 04-12 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email [email protected]
ELECTRICAL DATA
12/24vdc Input Voltage.
75mA Input controller current.
3 – N/C Normally Closed Inputs with screw terminals.
3 – N/O Normally Open Inputs with screw terminals.
5 Amp (Resistive) Fail Safe Lock Output.
5 Amp (Resistive) Fail Secure Lock Output.
Lock Status Output – SPDT (Form C) Dry Contact.
Green LED Indicator – Illuminated when lock is activated.
Size: 3.20” (81.28mm) W x 2.00” (50.8mm) L x 1.00” (25.4mm) H.
Fits all SDC Power Supplies. Requires 1 Module space.
Supplied with mounting screws and standoffs for J-box mounting.
POWER
SUPPLY
POWER
+
-
+
-
COM
N/C
N/O
MONITOR
OUTPUTS
FAIL SAFE
LOCK
FAIL SECURE
LOCK
or
D3
RELAY ACTIVE
INDICATOR
N/O REX INPUTS
N/C REX INPUTS
NOTE:
JUMPER ALL
UNUSED N/C
INPUTS
N/C
ACCESS
CONTROL
N/O
ACCESS
CONTROL
ADD JUMPER FOR
12VDC OPERATION
The SDC ACM-1 Access Control Module is an
installer friendly interface relay board designed to
release a magnetic locking device or electric strike,
to provide a lock status output and to provide easy
to use multiple wiring terminals for additional access
control REX (Request to Exit) inputs.
Operation
When any REX input is activated, the relay will release the
magnetic lock or electric strike. The Lock Status Output will
change state and the green LED will illuminate.
Compatible with any Request to Exit (REX) output, i.e.
Request-to-Exit Push Bar, Keypad, Card Reader, Motion
Sensor, Push Button or Key Switch.
C NC C NC C NC C NO C NO C NO
ACTIVE
SECURITY DOOR CONTROLS
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]