Cr-td,lr control modules, Security door controls, Installation wiring diagram door control modules – SDC FB4DC User Manual
Page 3: Latch outputs, Release, Outputs

P:\INSTALLATION INST\POWER SUPPLY\INST-CR_TR.vsd REV -
02-13 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email [email protected]
INSTALLATION WIRING DIAGRAM
DOOR CONTROL MODULES
SECURITY DOOR CONTROLS
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]
LR LATCHING RELAY MODULE
1. Momentarily activating the Latch input
activates and latches the lock output .
2. Momentarily activating the Release input
releases the lock output
6
5
4
3
2
1
S4 S5
S3 S2
FUSE
2 1
1
2
1
1
1
0
9
8
7
FAIL SAFE
LOCK
POWER
-
+
LATCH
OUTPUTS
LR
1 SPDT voltage output Max. 5 amp @ 12/24VDC
LATCH
COM
RESET
N/O
N/O
RELEASE
CR CONTROL RELAY MODULE
1. Select wet or dry trigger input.
2. Wet trigger input must be the
same as output voltage, AC or DC.
3. N/O trigger inputs shown. When
using N/C trigger inputs, outputs
are reversed.
6
5
4
3
2
1
S4 S5
S3 S2
FUSE
2 1
1
2
1
1
1
0
9
8
7
FAIL SECURE
LOCK
FAIL SAFE
LOCK
N/O
COM
N/C
AUXILIARY
CONTACTS
(DRY)
POWER
-
+
WET
TRIGGER INPUT
-
+
TRIGGER WET MODE
(APPLYING POWER RELEASES LOCK)
TRIGGER DRY MODE
(CLOSING SWITCH RELEASES LOCK)
OUTPUTS
N/O
1 SPDT voltage output Max. 5 amp @ 12/24VDC
1 SPDT dry contact 5 amp @ 30VAC
CR
6
5
4
3
2
1
S4 S5
S3 S2
FUSE
2 1
1
2
1
1
1
0
9
8
7
FAIL SECURE
LOCK
FAIL SAFE
LOCK
N/O
COM
N/C
AUXILIARY
CONTACTS
(DRY)
POWER
-
+
WET
TRIGGER INPUT
-
+
TIME
ADJUST
OUTPUTS
N/C
N/O
RESET
TIMER RANGE:
1 to 120 SECONDS
1-120 Second Adjustable time delay. 1 SPDT voltage output
Max. 5 amp @ 12/24VDC. 1 SPDT dry contact 5 amp @ 30VAC
TD TIME DELAY RELAY MODULE
1. Wet and dry trigger input may be used.
2. Wet trigger input may be 12V or 24V
AC or DC.
3. Normally off wet trigger input shown.
When using normally on trigger input,
outputs are reversed.
4. Reset; adding door position switch resets
timer to assure immediate relocking when
door closes to guard against unauthorized
entry of following pedestrian.
DRY
TRIGGER
INPUTS
TD