beautypg.com

Page 2 3. heaters & tube kits, Table 1: model configurations – Schwank ATH Brooder/Agricultural Series User Manual

Page 6

background image

GP-MATH-BX-10A

ATH / IA Manual

RD: Nov, 2005

RL: 10

KH

NOTE: Where required, the ATH / IA series heaters will be supplied with the turbulators, snugly installed into the

end tube(s) of the system configurations.

MODEL

OVERALL

HEATER
LENGTH

BTU/HOUR INPUT

U.S.*: 0 TO 2000 FT ABOVE SEA LEVEL

Canada: 0 TO 4500 FT ABOVE SEA LEVEL

TURBULATOR

REQUIRED

LENGTH

GAS

PRESSURE &

ELECTRICAL

SHIPPING

WEIGHT

(LBS.)

ATH / IA 130-50

50' 0”

130,000

Not Required

LINE

MINIMUM

5" W.C. N.G.

11" W.C. L.P.








LINE

MAXIMUM

14" W.C. N.G.

14" W.C. L.P.







MANIFOLD

3½" W.C. N.

G. 10" W.C. L.

P.

½" INLET






ELECTRICAL

120V, 60 HZ

239

ATH / IA 130-40

40’ 4”

10'

195

ATH / IA 130-30

30’ 8”

14'

150

ATH / IA 110-50

50’ 0”

110,000

Not Required

239

ATH / IA 110-40

40’ 4”

10'

195

ATH / IA 110-30

30’ 8”

14'

150

ATH / IA 80-40

40’ 4”

80,000

10’

195

ATH / IA 80-30

30’ 8”

14'

150

ATH / IA 80-20

21’ 0”

14'

106

ATH / IA 60-40

40’ 4”

60,000

10’

199

ATH / IA 60-30

30’ 8”

14’

150

ATH / IA 60-20

21’ 0”

14'

106

ATH / IA 45-20

21’ 0”

5’

106

ATH / IA 45-10

11’ 4”

5’

60

45,000

* In the U.S.: Orifice kits available for elevations above 2000 ft