Schwank ATH Brooder/Agricultural Series User Manual
Page 12
GP-MATH-BX-10A
ATH / IA Manual
RD: Nov, 2005
RL: 10
KH
8. REFLECTOR INSTALLATION
Page 8
TABLE 4
FIGURE 6 MOUNTING REFLECTOR END CAP
1
Reflector End Cap Flange
protruding over and under
the Reflector
2
Screws securing Reflector
to End Cap
3
Opening for Tube
4
Focus Shield Reflector
MODEL
TURBULATOR
LENGTH
(IF REQUIRED)
ATH / IA 130-50
not required
ATH / IA 130-40
10'
ATH / IA 130-30
14'
ATH / IA 110-50
not required
ATH / IA 110-40
10'
ATH / IA 110-30
14’
ATH / IA 80-40
10’
ATH / IA 80-30
14’
MODEL
TURBULATOR
LENGTH
(IF REQUIRED)
ATH / IA 80-20
14’
ATH / IA 60-40
10'
ATH / IA 60-30
14’
ATH / IA 60-20
14'
ATH / IA 45-20
5’
ATH / IA 45-10
5’
1
4
3
2
After burner and tubes have been installed, slide the focus shield reflectors one at a time into
the wire hangers. As each successive focus shield reflector is installed on an in-line installa-
tion, the ends of the focus shield reflectors will overlap to provide continuous coverage over the
entire tube system. The overlapping joints
MUST BE FASTENED
together.
Note: that for both horizontal and angle mounting, the tube must be level. Improper mounting
can result in overheating of controls and combustible materials. Use only non-combustible
mounting hardware. Side reflectors can be added to the heaters as an option. They should be
secured directly to the focus shield reflector using "S" hooks or chain. Drill three holes into fo-
cus shield reflector flange along side, which match up with three holes already in side reflector.
Mount side reflector as close as possible to the focus shield reflector.