beautypg.com

Schwank ecoSchwank Millivolt User Manual

Page 8

background image

ecoSchwank-MILLIVOLT / IL-MILLIVOLT Manual

IM090128

RD: JAN 2009

RL: 1D

BA

Under certain conditions, heater may discolour due to ambient air borne particle deposits on the outside sur-
face. These deposits in no way affect the operation of the heater nor the manufacturer’s warranties.

If heater back-fires during operation, then it must be turned off immediately.

Indication of back-firing:


A. Loud ignition noise, then followed by distinct

hissing sound.

B. Little or no visible burning on the ceramic

tile.

C. Combustion is taking place inside the burner

body.

Cause & remedy of back-firing:


A. Improper gas pressure entering the venturi

tube = check pressure.

B. Breakage of a ceramic tile and or gasketing =

replace damaged part.

C. Faulty sealing of the ceramic tile to the burner

body, caused by breakdown of gasketing ma-
terial = contact your Schwank distributor.

4. AIR BORN PARTICLES

5. SERVICING GUIDE

Servicing of heater is essential for continued efficient operation. Servicing should be carried out annu-
ally by qualified service personnel.

A. Clean the ceramic tile with low pressure compressed air. Avoid directing air stream at the gasketing

material between the tiles and heater body. The air pressure must be lower then 20 psi.


B. Clean the venturi tube with compressed air.

C. Clean the reflectors.

WARNING: