3 – Once the S&S® preformed breather hose has been cut, slide a dual wire spring clamp over each end.
Note: There are three dual wire spring clamps included in the kit. The two smaller diameter clamps go on the S&S breather hose. Push the 90° end of the
breather hose over the brass barb in the S&S air cleaner backplate followed by the dual wire spring clamp as illustrated in Picture 25.
4 – Route the straight end of the breather hose between the air cleaner and the frame rail and over the top of the rear rocker cover.
5 – Locate the S&S straight union breather fitting.
Note: The barbed ends of the straight union fitting have two different outside diameters. The small diameter end goes in the S&S breather hose and the
large diameter goes into the stock breather hose.
5 – Push the small outside diameter of the straight union fitting into the S&S formed breather hose followed by the dual wire spring clamp.
6 – Remove the cover from the stock breather hose that was put in place during the stock air box removal. Slide the large dual wire spring clamp
over the stock breather hose.
7 – Push the stock breather hose over the straight union fitting followed by the dual wire spring clamp.
8 – Rotate dual wire spring clamps so they are not contacting the frame rail.
Note: A small piece of black electrical tape should be applied to the frame rail where the breather fitting and dual wire spring clamps are close to
contacting the frame. This will reduce the risk of scratches to the frame.
9 – Secure the stock breather hose to the frame using the supplied 8” black wire tie. Picture 26 illustrates the proper breather hose routing, black
electrical tape location and secured breather hose to the frame.
10 – Install fuel line and connect to its original location from where it was removed.
Picture 26
Picture 25
Black Electrical Tape