SAFETY PRECAUTIONS

PERSONAL INJURY, DEATH, OR PROPERTY

DAMAGE HAZARD

Failure to follow this warning could result in personal injury,

death, or property damage.
Read and follow all instructions and warnings, including

labels shipped with or attached to unit before operating your

new air conditioner.

!

WARNING

Any time you see this symbol

in manuals, instructions and on

the unit, be aware of the potential for personal injury. There are

three levels of precaution:
DANGER identifies the most serious hazards which will result in
severe personal injury or death.
WARNING signifies hazards that could result in personal injury or

death.
CAUTION is used to identify unsafe practices which would result

in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in
enhanced installation, reliability, or operation.

PERSONAL INJURY, DEATH AND / OR PROPERTY

DAMAGE HAZARD

Failure to follow this warning could result in personal injury,

death or property damage.
Improper installation, adjustment, alteration, service,

maintenance, or use can cause explosion, fire, electrical shock,

or other conditions which may cause personal injury or

property damage.
Consult a qualified installer, service agency, your distributor

or branch for information or assistance. The qualified installer

or service agency must use factory--authorized kits or

accessories when modifying this product.

!

WARNING

GENERAL

The high wall fan coil unit provides quiet, maximum comfort. In
addition to cooling and/or heating, the high wall fan coil unit

matched with an outdoor condensing unit will filter and

dehumidify the air in the room to provide maximum comfort.
IMPORTANT: The high wall fan coil unit should be installed by
authorized personnel only; using approved tubing and accessories.
If technical assistance, service or repair is needed, contact the
installer or call 1--800--428--4326.
The high wall fan coil unit can be set up and operated from the
remote control (provided). If the remote is misplaced, the system

can be operated from the “Auto” setting on the unit.

Operating Modes:

The high wall fan coil unit has five operating modes.

S

Fan only

S

Auto (heat pump models only)

S

Heating (heat pump models only)

S

Cooling

S

Dehumidification (DRY)

Fan Only

In Fan Only mode, the system filters and circulates room air

without changing room air temperature.

Auto

In Auto mode, the system will automatically cool or heat the room
according to the user--selected set point.

Heating

In Heating mode, the system heats and filters room air.

Cooling

In Cooling mode, the system cools, dries and filters room air.

Dehumidification (DRY)

In Dehumidification mode, the system dries, filters and slightly

cools room air temperature. This mode does not take the place of
a dehumidifier.

Remote Control

The remote control transmits commands to set up and operate the

system. The control has a window display panel that shows the
current system status. The control can be secured to a surface

when used with the mounting bracket provided.