10 • 49-8104RK Standby Battery

Figure 6: Wiring the Standby Battery to a Beacon 800

11. Turn on power to the controller.

12. Turn on the controller.

13. When the controller has completed its startup sequence, re-connect the end of the

jumper wire to the battery terminal from which it was removed.

14. Close the standby battery housing door.

15. The on/off switch in the Beacon 200, Beacon 410, and Beacon 800 controls AC power

to the instruments. Verify that the standby battery is installed properly by flipping the
on/off switch to the off position and observing that the controller continues to operate
powered by the standby battery.

16. Flip the controller power switch to the on position.

Connections
Made With Wire
Nuts Provided

NC

NO

BAT+

AL

M

2

NO

C

C

NO
NC

RX
GND

+28V
TX

RESET

BUZ +

BUZ

RESET

BAT

FA

IL

A

L

M

1

Beacon 800 Housing

User
Installed
Jumper

Controller Terminal Strip

24

VD

C

Standby Battery Shown Without Door

C

NC