Purenex 7 Stage Reverse Osmosis System 100 GPG Per Day User Manual
Page 3

3
Thank you for choosing Watergeneral Reverse Osmosis Water Systems. You now own a superb Reverse Osmosis (RO) +
Deionization (DI) system that effectively reducing most contaminants, organic and inorganic compound, unwanted taste
and odor from tap water. It is designed to transform your tap water into distill water.
Read carefully and follow the instruction in this manual before proceeding with actual installation. Failure to do so could
result in personal injury or damage to the equipment or other property. Be sure to follow any special plumbing codes in
your area.
CHECK LIST:
1. Reverse Osmosis+DI Unit
2. for (RD-106) which includes water storage tank, 4 gallon outside volume (holds 3.2 gallon @60psi)
3. Installation kit consists tank ball valve, drain saddle valve, feed water adapter, feed water needle valve, faucet
assembly(for RD-106) , tubing, tube inserts
4. Installation manual
INSTALLATION KIT:
1. Chrome dispensing faucet
(for RD-106 only)
2. Tank ball valve
3. Drain saddle clamp
4. ¼” tubing
5. tube insert
6. ½” feed water adapter
7. needle valve or ball valve
RECOMMENDED TOOLS LIST
•
Variable speed drill
•
1/8” ¼”, 7/16”, and ½” drill bit
•
5/8, 9/16 open-end wrench, or adjustable wrench, pliers
•
Phillips screwdriver
•
Utility knife, or scissor
•
Teflon tape
OPERATING PARAMETER
•
Working pressure: 40 to 120 psi feed water pressure required, if below 40 psi, a booster pump is needed. We
have a RO system with built-in booster pump assembly.
•
Working temperature: 100 ~ 40 deg. F ( 37 ~ 4 deg. C )
•
If feed water has hardness level above 300 ppm, we recommend putting a water softener prior to the RO system.
•
If feed water has iron, rust problem, we recommend putting an iron filter prior to the RO system.
•
If feed water has bacteria problem, we recommend putting an ultra violet sterilizing system prior to RO system.
WARNING: Do not use this RO+DI system alone to treat water with bacteria problem or water source with unknown
quality.
WARNING: Do not connect HOT water source to this unit.
WARNING: Incorrect installation will VOID the warranty.