beautypg.com

Dca-45ssiu2 — generator shut-down procedure – Multiquip DCA45SSIU2 User Manual

Page 44

background image

PAGE 44 — DCA-45SSIU2 — OPERATION AND PARTS MANUAL (STD) — REV. #7 (06/13/07)

NORMAL SHUT-DOWN

To shutdown the generator, use the following procedure:

1. Switch the MAIN, AUX and GFCI circuit breakers

(Figure 61) to the “OFF” position (no load).

Figure 61. Main, AUX. and GFCI

Circuit Breakers (OFF)

EMERGENCY SHUT-DOWN

SHUTDOWN

1. To shut-down the engine in the event of an emergency,

switch the

MAIN, GFCI and LOAD (Figure 61) circuit

breakers to “OFF” position.

2. Turn the ignition switch key to the “STOP” position.

2. Push the engine throttle control lever inward (Figure 62)

to the “

LOW ” position.

3. Let the engine cool by running it for 3-5 minutes with no

load applied (circuit breakers in the off position).

4. Place the ignition switch (Figure 63) in the “STOP” position,

remove the key and store in a safe place.

Figure 62. Engine Throttle Control Lever (Low)

Figure 63. Ignition Switch (Off Position)

5. Remove

all loads from the generator.

DCA-45SSIU2 — GENERATOR SHUT-DOWN PROCEDURE