beautypg.com

Bunn CDS-3 User Manual

Page 32

background image

32

SERVICE (cont.)

COMPRESSOR & COMPONENTS (CDS-3) (cont.)

Compressor Run Capacitor:
1. Check for continuity across the terminals on the

compressor run capacitor.

If continuity is present as described, the run capacitor
is operating properly.
If continuity is not present as described, replace the
capacitor.

NOTE: If all the electrical components are operating prop-
erly and the compressor does not operate, there is an
internal mechanical problem. Replace the compressor.
Removal and Replacement:
Compressor Assy:
NOTE: Before removal of any refrigeration component
the refrigerant in the system must be reclaimed by a
licensed refrigeration repair person.
1. Disconnect the tubes from the condenser, accu-

mulator also remove access valve and tube..

2. Disconnect the compressor wiring harness from

the dispenser main wiring harness.

3. Remove the four .312"-18 screws, keps nuts and

washers securing the compressor to the chassis.
Set screws, nuts and washers aside for reassem-
bly.

4. Remove the four #8-32 locking screws securing

the component bracket to the dispenser chassis.

5. Pull the component bracket, with wires attached,

out of the chassis far enough to gain access to the
compressor.

6. Disconnect the compressor wiring harness from

the compressor.

7. Remove the two #8-32 screws securing the

contactor mounting bracket to the dispenser base.

8. Remove the contactor mounting bracket, contactor,

contactor cover and the compressor wiring har-
ness as an assembly. Set aside for reassembly.

9. Disconnect the fan leads from the main wiring

harness.

10. Remove the three #6 thread cutting screws secur-

ing the fan to the condenser shroud. Remove the
fan and set aside for reassembly.

11. Slide the compressor out the right side of the

dispenser.

12. Remove the four grommets and sleeves from the

old compressor and install them on the new com-
pressor.

13. Slide new compressor into position on the dis-

penser chassis, with the tube connections to the
front.

14. Secure compressor to the dispenser chassis using

four .312"-18 screws, washers and nuts.

15. Install the fan on the condenser shroud and secure

with three #6 thread cutting screws.

16. Reconnect the leads on the fan to the main har-

ness.

17. On dispensers serial number CDS0019500 - up

install the contactor bracket, contactor, contactor
cover and compressor wiring harness as an as-
sembly. Secure contactor bracket to the chassis
using two #8-32 screws.

18. Refer to Fig.17A and reconnect the wires to the

compressor.

19. Position the component bracket in the chassis and

secure with four #8-32 locking screws.

20. Reconnect tubes from the condenser and the ac-

cumulator to the compressor, also reconnect ac-
cess valve and tube.

21. Evacuate the system.

NOTE: When replacing the compressor it is recom-
mended that the dryer also be replaced.
22. Dispensers prior to serial number CDS0019500

recharge system with 25 oz. of Type R404A refrig-
erant. Design Pressures: High 320 - Low 44
Dispensers serial number CDS0019500 - up re-
charge system with 22 oz of type R404A refriger-
ant. Design Pressures: High 380 - Low 52

NOTE: The charging of the system must be done by a
licensed refrigeration repair person.

RED from
Relay T2
WHI from
Relay T4
BLK from
Relay T-5

FIG. 17A COMPRESSOR TERMINALS

P1819

27646 122200

This manual is related to the following products: