beautypg.com

Bunn CDS-3 User Manual

Page 26

background image

26

If continuity is present as described, the auger switch
is operating properly.

If continuity is not present as described, replace the
auger switch.

Removal and Replacement:
1. Pull the dispenser drawer out until the drawer hits

the drawer stop. Using a screwdriver gently pry up
on the drawer stop and remove the drawer from
the dispenser.

2. Remove the four #8-32 locking screws securing

the switch panel to the drawer.

3. Lift the switch panel with wires and L.E.D./adjust-

ment board out as an assembly.

4. Turn switch panel over and remove the wires from

the auger switch that is to be replaced.

5. Compress the clips on the back of the control panel

and gently push switch through the opening.

6. Push the new switch into the opening, with the “o”

on the switch to the outside, until the clips snap
into position.

7. Reconnect the wires to the switch. Refer to Fig. 8

when reconnecting wires.

8. Position the switch panel inside the drawer and

secure with four #8-32 locking screws.

9. Reinstall drawer.

FIG. 8 AUGER SWITCH TERMINALS

P1336

FIG. 7 AUGER ON/OFF SWITCHES

P1343

Location:

The auger switches are located inside the dispenser

drawer.

Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the white/green wire from the switch

to be tested and white/black wire from contactor
located on the outside bottom of the component
bracket .

3. With a voltmeter, check the voltage across the

white/green and the white/black wires and the
“ON/OFF” switch in the “ON” position. Connect the
dispenser to the power source. The indication
must be:
a) 120 volts ac for 120 volt models.
b) 230 volts ac for 230 volt models.

4. Disconnect the dispenser from the power source.

If voltage is present as described, reconnect the white/
black wire to the contactor and proceed to #5.
If voltage is not present as described, refer to the

Wiring Diagram

and check the dispenser wiring har-

ness.

5. Remove the white/blue wire from the right auger

switch, the white/brown wire from the left auger
switch, or the grey wire from the center auger switch.

6. With the auger switch to be tested in the “ON”

position check for continuity across the terminals.
Continuity must not be present when the switch is
in the “OFF” position.

SERVICE (cont.)

AUGER ON/OFF SWITCHES

27646 122200