TROUBLESHOOTING (cont.)
REMEDY
(A) The circuit breaker must not be
tripped.
(B) Refer to
Service
- Circuit Breaker
for testing procedures. See page 27.
Remove the lamps and check for
continuity across the base and tip.
Replace if necessary.
Refer to
Service
- Transformer for
testing procedures. See page 49.
Refer to
Service
- Lamp Holder/
Socket Assembly for testing proce-
dures. See page 44.
(A) The auger switch must be in the
"ON" position.
(B) Refer to
Service
- Auger ON/OFF
Switch(es) for testing procedures.
See page 26.
Refer to
Service
- Auger Motor
Capacitor(s) for testing procedures.
See page 23.
Refer to
Service
- Auger Motor(s) for
testing procedures. See page 22.
Refer to
Service
- Fan Motor for
testing procedures. See page 39.
The fan motor will run for approxi-
mately two minutes after compres-
sor shuts off.
PROBABLE CAUSE
3. Circuit Breaker
4. Lamps
5.Transformer
6. Lamp Holder/Socket Assy
1. Auger ON/OFF Switch(es)
2. Auger Motor Capacitor(s)
3. Auger Motor(s)
1. Fan Motor
1. Time Delay
PROBLEM
Hopper Display Lights not on (cont.)
Auger Motor won't turn
Fan not spinning (With adjustment
Board L.E.D.s ON steadily for two
minutes)
Fan spins after compressor shuts
off
27646 122200